CoChat

Quantification of cerebral hemoglobin as a function of oxygenation using near-infrared time-resolved spectroscopy in a piglet model of hypoxia

Open access
Ijichi, Sonoko, Kusaka, Takashi, Isobe, Kenich, Islam, Fahmida, Okubo, Kensuke, Okada, Hitoshi, Namba, Masanori, Kawada, Kou, Imai, Tadashi, Itoh, Susumu · 2005 · Journal of Biomedical Optics
Cited by 71

The DOI matches its Crossref record.

Abstract

Near-infrared spectroscopy (NIRS) has been used for measurement of cerebral hemoglobin (Hb) concentrations in neonates to study cerebral oxygenation and hemodynamics. We perform measurements by portable three-wavelength NIR time-resolved spectroscopy (TRS) in a piglet hypoxia model with various degrees of oxygenation to estimate the absorption coefficient (mu(a)) and reduced scattering coefficient (mu(s)') of the head. Measurements of absolute values of mu(a) at three wavelengths enable estimation of Hb concentration and Hb oxygen saturation in the head (SO2). However, there is a problem concerning which background absorption should be used to estimate Hb concentration in the head derived from mu(a) at three wavelengths because it is different from a simple in vitro model. Therefore, we use two different background absorption values with the assumption that background absorption is due only to 85% (by volume) water or that background absorption is equal to absorption of the piglet head with blood exchange transfusion by fluorocarbon (FC), and we compared SO2 measured by TRS with arterial Hb oxygen saturation (SaO2) and sagittal sinus venous Hb oxygen saturation (SvO2) measured by a co-oximeter at several inspired fractional O2(FI(O2)) concentrations. We find that SO2 values using the absorption (abs) of the piglet head with blood exchange transfusion (BET) by FC are not significantly different from SO2 values using the water-only background at FI(O2) in the range of 15 to 100%, but that the values using abs of the head with BET by FC are lower than the values using the water-only background at FI(O2) in the range of 12 to 4%. The SO2 values calculated from the water-only background are higher than those of SaO2 at FI(O2) in the range of 10 to 4%. However, SO2 values using the abs of the head with BET by FC are between those of SaO2 and SvO2 over the whole range of FI(O2). Therefore, abs of the head with BET by FC is more useful for estimation of the absolute values of oxyHb and deoxyHb of the piglet head.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1117/1.1899184

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 71

Metadata

Authors
Ijichi, S., Kusaka, T., Isobe, K., Islam, F., Okubo, K., Okada, H., Namba, M., Kawada, K., Imai, T., & Itoh, S.
Venue
Journal of Biomedical Optics
Published
2005
Volume
10
Issue
2
Pages
024026
ISSN
1083-3668 (ISSN-L)
OpenAlex
W2123377272
Cited by
71
References
0
FWCI
3.33
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Quantification of cerebral hemoglobin as a function of oxygenation using near-infrared time-resolved spectroscopy in a piglet model of hypoxia. https://app.cochat.ai/papers/10.1117/1.1899184
The paper
Ijichi, S., Kusaka, T., Isobe, K., Islam, F., Okubo, K., Okada, H., Namba, M., Kawada, K., Imai, T., & Itoh, S. (2005). Quantification of cerebral hemoglobin as a function of oxygenation using near-infrared time-resolved spectroscopy in a piglet model of hypoxia. Journal of Biomedical Optics. https://doi.org/10.1117/1.1899184

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.