Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 321

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

High-resolution, real-time three-dimensional shape measurement

Huang, Peisen S.·2006·Optical Engineering

Abstract

We describe a high-resolution, real-time 3-D shape measurement system based on a digital fringe projection and phase-shifting technique. It utilizes a single-chip digital light processing projector to project computer-generated fringe patterns onto the object, and a high-speed CCD camera synchronized with the projector to acquire the fringe images at a frame rate of 120 frames/s. A color CCD camera is also used to capture images for texture mapping. Based on a three-step phase-shifting technique, each frame of the 3-D shape is reconstructed using three consecutive fringe images. Therefore the 3-D data acquisition speed of the system is 40 frames/s. With this system, together with the fast three-step phase-shifting algorithm and parallel processing software we developed, high-resolution, real-time 3-D shape measurement is realized at a frame rate of up to 40 frames/s and a resolution of 532×500 points per frame.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1117/1.2402128

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 321

Metadata

Authors
Huang, P. S.
Venue
Optical Engineering
Published
2006-12-01
Volume
45
Issue
12
Pages
123601
ISSN
0091-3286 (ISSN-L)
OpenAlex
W2002896099
Cited by
321
References
1
FWCI
18.43
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High-resolution, real-time three-dimensional shape measurement. https://app.cochat.ai/papers/10.1117/1.2402128
The paper
Huang, P. S. (2006). High-resolution, real-time three-dimensional shape measurement. Optical Engineering. https://doi.org/10.1117/1.2402128

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.