Prospects for the diagnosis of breast cancer by noninvasive probing of calcifications using transmission Raman spectroscopy
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Breast calcifications can be found in both benign and malignant lesions, and the composition of these calcifications can indicate the possible disease state. As current practices such as mammography and histopathology examine the morphology of the specimen, they cannot reliably distinguish between the two types of calcification, which frequently are the only mammographic features that indicate the presence of a cancerous lesion. Raman spectroscopy is an optical technique capable of obtaining biochemical information of a sample in situ. We demonstrate for the first time the noninvasive recovery of Raman spectra of calcified materials buried within a chicken breast tissue slab 16 mm thick, achieved using transmission Raman spectroscopy. The spectra of both calcium hydroxyapatite (HAP) and calcium oxalate monohydrate (COM) are obtained and chemically identified. The experimental geometry and gross insensitivity of the Raman signal to the depth of the calcified lesion makes the concept potentially well suited for probing human female breasts, in conjunction with existing mammography or ultrasound, to provide complementary data in the early diagnosis of breast cancer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Near‐infrared Raman spectroscopy for the classification of epithelial pre‐cancers and cancers
Stone, N., Kendall, C., Shepherd, N., Crow, P., & Barr, H. (2002) · Journal of Raman Spectroscopy · doi:10.1002/jrs.882 · Cited by 472
Self-citation
Cited by
Using Raman spectroscopy to characterize biological materials
Butler, H. J., Ashton, L., Bird, B., Cinque, G., Curtis, K., Dorney, J., Esmonde-White, K., Fullwood, N. J., Gardner, B., Martin-Hirsch, P. L., et al. (2016) · Nature Protocols · doi:10.1038/nprot.2016.036 · Cited by 1,309
Self-citationKong, K., Kendall, C., Stone, N., & Notingher, I. (2015) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2015.03.009 · Cited by 653
Self-citationApplications of Raman spectroscopy in cancer diagnosis
Auner, G. W., Koya, S. K., Huang, C., Broadbent, B., Trexler, M., Auner, Z., Elias, A., Mehne, K. C., & Brusatori, M. A. (2018) · Cancer and Metastasis Reviews · doi:10.1007/s10555-018-9770-9 · Cited by 385
Surface-enhanced Raman spectroscopy: a half-century historical perspective
Yi, J., You, E.-M., Hu, R., Wu, D.-Y., Liu, G.-K., Yang, Z.-L., Zhang, H., Gu, Y., Wang, Y.-H., Wang, X., et al. (2025) · Chemical Society Reviews · doi:10.1039/d4cs00883a · Cited by 382
Surface enhanced spatially offset Raman spectroscopic (SESORS) imaging – the next dimension
Stone, N., Kerssens, M., Lloyd, G. R., Faulds, K., Graham, D., & Matousek, P. (2011) · Chemical Science · doi:10.1039/c0sc00570c · Cited by 183
Self-citation
Metadata
- Authors
- Matousek, P., & Stone, N.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2007
- Volume
- 12
- Issue
- 2
- Pages
- 024008
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2113069378
- Cited by
- 102
- References
- 1
- FWCI
- 4.78
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Prospects for the diagnosis of breast cancer by noninvasive probing of calcifications using transmission Raman spectroscopy. https://app.cochat.ai/papers/10.1117/1.2718934
- The paper
- Matousek, P., & Stone, N. (2007). Prospects for the diagnosis of breast cancer by noninvasive probing of calcifications using transmission Raman spectroscopy. Journal of Biomedical Optics. https://doi.org/10.1117/1.2718934
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.