Abstract
Mosaicing of confocal images enables observation of nuclear morphology in large areas of tissue. An application of interest is rapid detection of basal cell carcinomas (BCCs) in skin excisions during Mohs surgery. A mosaic is currently created in less than 9 min, whereas preparing frozen histology requires 20 to 45 min for an excision. In reflectance mosaics, using acetic acid as a contrast agent to brighten nuclei, large and densely nucleated BCC tumors were detectable in fields of view of 12 x 12 mm (which is equivalent to a 2x-magnified view as required by Mohs surgeons). However, small and sparsely nucleated tumors remained undetectable. Their diminutive size within the large field of view resulted in weak light backscatter and contrast relative to the bright surrounding normal dermis. In fluorescence, a nuclear-specific contrast agent may be used and light emission collected specifically from nuclei but almost none from the dermis. Acridine orange of concentration 1 mM stains nuclei in 20 s with high specificity and strongly enhances nuclear-to-dermis contrast of BCCs. Comparison of fluorescence mosaics to histology shows that both large and small tumors are detectable. The results demonstrate the feasibility of confocal mosaicing microscopy toward rapid surgical pathology to potentially expedite and guide surgery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Light-sheet microscopy for slide-free non-destructive pathology of large clinical specimens
Glaser, A. K., Reder, N. P., Chen, Y., McCarty, E. F., Yin, C., Wei, L., Wang, Y., True, L. D., & Liu, J. T. C. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0084 · Cited by 419
A survey of methods for 3D histology reconstruction
Pichat, J., Iglesias, J. E., Yousry, T., Ourselin, S., & Modat, M. (2018) · Medical Image Analysis · doi:10.1016/j.media.2018.02.004 · Cited by 207
“Overlap is recommended to account for field curvature-induced artefacts in the image and avoid loss of detail at the edges between images; Gareau et al. (2008) included 10% overlap in the translation step distance.”
BackgroundCao, R., Nelson, S. D., Davis, S., Liang, Y., Luo, Y., Zhang, Y., Crawford, B., & Wang, L. V. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00940-z · Cited by 177
Metadata
- Authors
- Gareau, D. S., Li, Y., Huang, B., Eastman, Z., Nehal, K. S., & Rajadhyaksha, M.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2008
- Volume
- 13
- Issue
- 5
- Pages
- 054001
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W1978085863
- Cited by
- 158
- References
- 0
- FWCI
- 6.13
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Confocal mosaicing microscopy in Mohs skin excisions: feasibility of rapid surgical pathology. https://app.cochat.ai/papers/10.1117/1.2981828
- The paper
- Gareau, D. S., Li, Y., Huang, B., Eastman, Z., Nehal, K. S., & Rajadhyaksha, M. (2008). Confocal mosaicing microscopy in Mohs skin excisions: feasibility of rapid surgical pathology. Journal of Biomedical Optics. https://doi.org/10.1117/1.2981828
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.