The DOI matches its Crossref record.
Fluorescence lifetime imaging microscopy for brain tumor image-guided surgery
Open accessAbstract
We demonstrate for the first time the application of an endoscopic fluorescence lifetime imaging microscopy (FLIM) system to the intraoperative diagnosis of glioblastoma multiforme (GBM). The clinically compatible FLIM prototype integrates a gated (down to 0.2 ns) intensifier imaging system with a fiber-bundle (fiber image guide of 0.5 mm diameter, 10,000 fibers with a gradient index lens objective 0.5 NA, and 4 mm field of view) to provide intraoperative access to the surgical field. Experiments conducted in three patients undergoing craniotomy for tumor resection demonstrate that FLIM-derived parameters allow for delineation of tumor from normal cortex. For example, at 460±25-nm wavelength band emission corresponding to NADH/NADPH fluorescence, GBM exhibited a weaker fluorescence intensity (35% less, p-value<0.05) and a longer lifetime τGBM-Amean=1.59±0.24 ns than normal cortex τNC-Amean=1.28±0.04 ns (p-value<0.005). Current results demonstrate the potential use of FLIM as a tool for image-guided surgery of brain tumors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Datta, R., Heaster, T. M., Sharick, J. T., Gillette, A. A., & Skala, M. C. (2020) · Journal of Biomedical Optics · doi:10.1117/1.jbo.25.7.071203 · Cited by 880
Separating NADH and NADPH fluorescence in live cells and tissues using FLIM
Blacker, T. S., Mann, Z. F., Gale, J. E., Ziegler, M., Bain, A. J., Szabadkai, G., & Duchen, M. R. (2014) · Nature Communications · doi:10.1038/ncomms4936 · Cited by 575
Fluorescence lifetime imaging (FLIM): Basic concepts and some recent developments
Suhling, K., Hirvonen, L. M., Levitt, J. A., Chung, P.-H., Tregidgo, C., Le Marois, A., Rusakov, D. A., Zheng, K., Ameer-Beg, S., Poland, S., et al. (2015) · Medical Photonics · doi:10.1016/j.medpho.2014.12.001 · Cited by 313
Optical Image-Guided Cancer Surgery: Challenges and Limitations
Keereweer, S., Van Driel, P. B. A. A., Snoeks, T. J. A., Kerrebijn, J. D. F., Baatenburg de Jong, R. J., Vahrmeijer, A. L., Sterenborg, H. J. C. M., & Löwik, C. W. G. M. (2013) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-12-3598 · Cited by 270
Fluorescence Lifetime Techniques in Medical Applications
Marcu, L. (2012) · Annals of Biomedical Engineering · doi:10.1007/s10439-011-0495-y · Cited by 257
Metadata
- Authors
- Hatami, N.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2010-09-01
- Volume
- 15
- Issue
- 5
- Pages
- 056022
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2088341766
- Cited by
- 171
- References
- 0
- FWCI
- 6.75
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fluorescence lifetime imaging microscopy for brain tumor image-guided surgery. https://app.cochat.ai/papers/10.1117/1.3486612
- The paper
- Hatami, N. (2010). Fluorescence lifetime imaging microscopy for brain tumor image-guided surgery. Journal of Biomedical Optics. https://doi.org/10.1117/1.3486612
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.