Simultaneous measurement of breathing rate and heart rate using a microbend multimode fiber optic sensor
Open accessThe DOI matches its Crossref record.
Abstract
We propose and demonstrate the feasibility of using a highly sensitive microbend multimode fiber optic sensor for simultaneous measurement of breathing rate (BR) and heart rate (HR). The sensing system consists of a transceiver, microbend multimode fiber, and a computer. The transceiver is comprised of an optical transmitter, an optical receiver, and circuits for data communication with the computer via Bluetooth. Comparative experiments conducted between the sensor and predicate commercial physiologic devices showed an accuracy of ±2 bpm for both BR and HR measurement. Our preliminary study of simultaneous measurement of BR and HR in a clinical trial conducted on 11 healthy subjects during magnetic resonance imaging (MRI) also showed very good agreement with measurements obtained from conventional MR-compatible devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Application Challenges in Fiber and Textile Electronics
Wang, L., Fu, X., He, J., Shi, X., Chen, T., Chen, P., Wang, B., & Peng, H. (2020) · Advanced Materials · doi:10.1002/adma.201901971 · Cited by 477
The future of sleep health: a data-driven revolution in sleep science and medicine
Perez-Pozuelo, I., Zhai, B., Palotti, J., Mall, R., Aupetit, M., Garcia-Gomez, J. M., Taheri, S., Guan, Y., & Fernandez-Luque, L. (2020) · npj Digital Medicine · doi:10.1038/s41746-020-0244-4 · Cited by 311
Recent development of respiratory rate measurement technologies
Liu, H., Allen, J., Zheng, D., & Chen, F. (2019) · Physiological Measurement · doi:10.1088/1361-6579/ab299e · Cited by 266
Ballistocardiogram signal processing: a review
Sadek, I., Biswas, J., & Abdulrazak, B. (2019) · Health Information Science and Systems · doi:10.1007/s13755-019-0071-7 · Cited by 216
“[90] reported related results using data collected from eleven healthy subjects (6 males and five females) during MRI.”
BackgroundLeal-Junior, A., Avellar, L., Frizera, A., & Marques, C. (2020) · Scientific Reports · doi:10.1038/s41598-020-70880-8 · Cited by 183
Metadata
- Authors
- Chen, Z., Lau, D., Teo, J. T., Ng, S. H., Yang, X., & Kei, P. L.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2014-05-01
- Volume
- 19
- Issue
- 5
- Pages
- 057001
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2128307414
- Cited by
- 112
- References
- 0
- FWCI
- 4.47
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Simultaneous measurement of breathing rate and heart rate using a microbend multimode fiber optic sensor. https://app.cochat.ai/papers/10.1117/1.jbo.19.5.057001
- The paper
- Chen, Z., Lau, D., Teo, J. T., Ng, S. H., Yang, X., & Kei, P. L. (2014). Simultaneous measurement of breathing rate and heart rate using a microbend multimode fiber optic sensor. Journal of Biomedical Optics. https://doi.org/10.1117/1.jbo.19.5.057001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.