Structural similarity index family for image quality assessment in radiological images
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The structural similarity index (SSIM) family is a set of metrics that has demonstrated good agreement with human observers in tasks using reference images. These metrics analyze the viewing distance, edge information between the reference and the test images, changed and preserved edges, textures, and structural similarity of the images. Eight metrics based on that family are proposed. This new set of metrics, together with another eight well-known SSIM family metrics, was tested to predict human performance in some specific tasks closely related to the evaluation of radiological medical images. We used a database of radiological images, comprising different acquisition techniques (MRI and plain films). This database was distorted with different types of distortions (Gaussian blur, noise, etc.) and different levels of degradation. These images were analyzed by a board of radiologists with a double-stimulus methodology, and their results were compared with those obtained from the 16 metrics analyzed and proposed in this research. Our experimental results showed that the readings of human observers were sensitive to the changes and preservation of the edge information between the reference and test images, changes and preservation in the texture, structural component of the images, and simulation of multiple viewing distances. These results showed that several metrics that apply this multifactorial approach (4-G-SSIM, 4-MS-G-SSIM, [Formula: see text], and [Formula: see text]) can be used as good surrogates of a radiologist to analyze the medical quality of an image in an environment with a reference image.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Image quality assessment: from error visibility to structural similarity
Wang, Z., Bovik, A. C., Sheikh, H. R., & Simoncelli, E. P. (2004) · IEEE Transactions on Image Processing · doi:10.1109/tip.2003.819861 · Cited by 57,892
Multiscale structural similarity for image quality assessment
Wang, Z., Simoncelli, E. P., & Bovik, A. C. (2004) · The Thrity-Seventh Asilomar Conference on Signals, Systems & Computers, 2003 · doi:10.1109/acssc.2003.1292216 · Cited by 6,253
The kappa statistic in reliability studies: use, interpretation, and sample size requirements
Sim, J., & Wright, C. C. (2005) · Physical Therapy · doi:10.1093/ptj/85.3.257 · Cited by 4,093
Cited by
Assessing the trustworthiness of saliency maps for localizing abnormalities in medical imaging
Arun, N., Gaw, N., Singh, P., Chang, K., Aggarwal, M., Chen, B., Hoebel, K., Gupta, S., Patel, J., Gidwani, M., et al. (2021) · Radiology: Artificial Intelligence · doi:10.1148/ryai.2021200267 · Cited by 342
“Note that a low base-line of 0.5 for SSIM was chosen because SSIM ranges from 0 (for lack of any structural similarity) to 1 (for identical structural similarity), and 0.5 marks the midpoint for whether the SSIM is more structurally similar or dissimilar (24).”
BackgroundInfluentialProspects of Structural Similarity Index for Medical Image Analysis
Mudeng, V., Kim, M., & Choe, S.-W. (2022) · Applied Sciences · doi:10.3390/app12083754 · Cited by 101
“reported inspecting bone plain films, magnetic resonance, and chest plain films, selecting four medical doctors with diagnostic experiences in measuring such images to participate [5].”
Background
Metadata
- Authors
- Renieblas, G. P., Nogués, A. T., González, A. M., Gómez-Leon, N., & del Castillo, E. G.
- Venue
- Journal of Medical Imaging
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2017-07-26
- Volume
- 4
- Issue
- 3
- Pages
- 035501
- ISSN
- 2329-4302 (ISSN-L)
- OpenAlex
- W2737022104
- Cited by
- 166
- References
- 3
- FWCI
- 4.04
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.