The DOI matches its Crossref record.
Frequency-domain multichannel optical detector for noninvasive tissue spectroscopy and oximetry
Open accessAbstract
We have designed a multisource frequency-domain spectrometer for the optical study of biological tissues. Eight multiplexed, intensity-modulated LEDs are employed as the light sources. Four of them emit light at a peak wavelength of 715 nm (λ1); the other four, 850 nm (λ2). The frequency of intensity modulation is 120 MHz. This instrument measures the frequency-domain parameters phase, dc intensity, and ac amplitude at the two wavelengths λ1 and λ2 and for different distances between light source and detector. From these frequency-domain raw data, the absolute values of the absorption and reduced scattering coefficients of tissue at λ1 and λ2 are obtained. The oxy- and deoxyhemoglobin concentrations, and hence the hemoglobin saturation, are then analytically derived from the molar extinction coefficients. Acquisition times as short as hundreds of milliseconds provide real-time monitoring of the measured parameters. We performed a systematic test in vitro to quantify the precision and accuracy of the instrument reading. We also report in vivo measurements. This spectrometer can be packaged as a compact portable unit.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Quantification in tissue near–infrared spectroscopy
Delpy, D. T., & Cope, M. (1997) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.1997.0046 · Cited by 507
Noninvasive determination of the optical properties of two-layered turbid media
Kienle, A., Patterson, M. S., Dögnitz, N., Bays, R., Wagnières, G., & van den Bergh, H. (1998) · Applied Optics · doi:10.1364/ao.37.000779 · Cited by 294
Fantini, S., Hueber, D., Franceschini, M. A., Gratton, E., Rosenfeld, W., Stubblefield, P. G., Maulik, D., & Stankovic, M. R. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/6/308 · Cited by 277
Self-citationFranceschini, M. A., Fantini, S., Paunescu, L. A., Maier, J. S., & Gratton, E. (1998) · Applied Optics · doi:10.1364/ao.37.007447 · Cited by 172
Self-citationFarzam, P., Starkweather, Z., & Franceschini, M. A. (2018) · Physiological Reports · doi:10.14814/phy2.13664 · Cited by 89
Self-citation
Metadata
- Authors
- Fantini, S.
- Venue
- Optical Engineering
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 1995-01-01
- Volume
- 34
- Issue
- 1
- Pages
- 32
- ISSN
- 0091-3286 (ISSN-L)
- OpenAlex
- W1981097671
- Cited by
- 330
- References
- 0
- FWCI
- 11.09
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Frequency-domain multichannel optical detector for noninvasive tissue spectroscopy and oximetry. https://app.cochat.ai/papers/10.1117/12.183988
- The paper
- Fantini, S. (1995). Frequency-domain multichannel optical detector for noninvasive tissue spectroscopy and oximetry. Optical Engineering. https://doi.org/10.1117/12.183988
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.