Fabrication of SiC aspheric mirrors with low mid-spatial error
Abstract
Recent experience with finishing off-axis parabolas and other conic surfaces is demonstrated by some examples that illustrate surface accuracy – not only in terms of traditional metrics, but also in terms of specified ranges of spatial frequency. Particular attention is given to the topic of interferometric metrology, and the extent to which we can effectively characterize mid-spatial frequency errors. The presence of mid-spatial errors can appear even more dominant in hard ceramics like SiC as compared with glass – reasons for this are suggested. This paper will discuss how controlled force grinding, robotic polishing, and surface smoothing can be employed to minimize and mitigate mid-spatial errors in fast silicon carbide aspheric mirrors. Recent experience and results are presented on two SiC mirrors finished by Aperture Optical Sciences Inc.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Machine vibrations or non-smooth movements of the stage can cause MSF errors.
“or by various machine vibrations or non-smooth movements of the stage[4, 5].”
From Smoothing tool design and performance during subaperture glass polishing (2023) · cites this paper as [4]
Cited by
Sorted by citations
Smoothing tool design and performance during subaperture glass polishing
Suratwala, T., Tham, G., Steele, R., Wong, L., Menapace, J., Ray, N., & Bauman, B. (2023) · Applied Optics · doi:10.1364/ao.482739 · Cited by 11 · see citing works
- Authors
- Tinker, F., & Xin, K.
- Venue
- SPIE Proceedings
- Publisher
- SPIE
- Published
- 2013-09-30
- Volume
- 8837
- Pages
- 88370M
- ISSN
- 0277-786X (ISSN-L)
- OpenAlex
- W2076066905
- Cited by
- 9
- References
- 0
- Citations by year
- 2023: 1 · 2021: 3 · 2019: 1 · 2017: 1 · 2016: 2 · 2014: 1
- FWCI
- 1.98
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Surface Polishing Techniques
- Physical Sciences › Engineering › Computational Mechanics › Surface Roughness and Optical Measurements
- Physical Sciences › Engineering › Biomedical Engineering › Advanced optical system design
- Keywords
- silicon carbide, aspheric mirrors, mid-spatial frequency error, interferometric metrology, surface accuracy, robotic polishing, surface smoothing, hard ceramics, space optics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review