Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 190

The DOI matches its Crossref record.

HYDICE system: implementation and performance

Basedow, Robert W., Carmer, Dwayne C., Anderson, Mark E. · 1995 · SPIE Proceedings

Abstract

This paper presents an overview of the HYDICE hyperspectral system, sponsored by the Naval Research Laboratory, built by Hughes Danbury Optical Systems and flown by the Environmental Research Institute of Michigan. HYDICE stands for the Hyperspectral Digital Imagery Collection Experiment. The sensor component of this experiment was procured as a dual use initiative. This unique sensor has pushbroom imaging optics with a prism spectrometer and InSb focal plane array detector. It represents a significant advance in signal- to-noise ratio, spatial and spectral resolution, and radiometric accuracy. This paper describes the system that has been built and flight tested. Differences between the original design and the actual hardware are indicated. The integration of the sensor with the aircraft is explained, including an overview of other on-board capabilities. The way in which the sensor system can be operated is illustrated. Flight test data are currently being analyzed, but selected laboratory performance tests are shown. The overall system flight performance is assessed qualitatively, with reference to laboratory data.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1117/12.210881

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 190

Metadata

Authors
Basedow, R. W., Carmer, D. C., & Anderson, M. E.
Venue
SPIE Proceedings
Publisher
SPIE
Published
1995-06-12
Volume
2480
Pages
258
ISSN
0277-786X (ISSN-L)
OpenAlex
W2070615500
Cited by
190
References
0
FWCI
27.68
Type
conference paper
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: HYDICE system: implementation and performance. https://app.cochat.ai/papers/10.1117/12.210881
The paper
Basedow, R. W., Carmer, D. C., & Anderson, M. E. (1995). HYDICE system: implementation and performance. SPIE Proceedings. https://doi.org/10.1117/12.210881

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.