Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 214

The DOI matches its Crossref record.

Three-photon excitation in fluorescence microscopy

Open access
Hell, Stefan W. · 1996 · Journal of Biomedical Optics

Abstract

We show experiments proving the feasibility of scanning fluorescence microscopy by three-photon excitation. Three-photon excitation fluorescence axial images are shown of polystyrene beads stained with the fluorophore 2,5-bis(4-biphenyl)oxazole (BBO). Three-photon excitation is performed at an excitation wavelength of 900 nm and with pulses of 130 fs duration provided by a mode-locked titanium sapphire laser. Fluorescence is collected between 350 and 450 nm. The fluorescence image signal features a third-order dependence on the excitation power, also providing intrinsic 3-D imaging. The resolution of a three-photon excitation microscope is increased over that of a comparable two-photon excitation microscope.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1117/12.229062

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 214

Metadata

Authors
Hell, S. W.
Venue
Journal of Biomedical Optics
Published
1996
Volume
1
Issue
1
Pages
71
ISSN
1083-3668 (ISSN-L)
OpenAlex
W2120435564
Cited by
214
References
0
FWCI
10.57
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Three-photon excitation in fluorescence microscopy. https://app.cochat.ai/papers/10.1117/12.229062
The paper
Hell, S. W. (1996). Three-photon excitation in fluorescence microscopy. Journal of Biomedical Optics. https://doi.org/10.1117/12.229062

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.