The DOI matches its Crossref record.
Multispectral photoacoustic Doppler velocimetry with intensity modulated high repetition supercontinnum laser pulses
Abstract
Previous photoacoustic flow measurements have been demonstrated with various modalities including Doppler frequency shift measurement from intensity modulated continuous laser wave and pulsed photoacoustic Doppler cross- correlation from nanosecond laser pulse. Here, we propose and demonstrate a new type of photoacoustic Doppler velocimetry based on a hybrid approach: we applied a supercontinnum laser source with picosecond pulse and 40 MHz repetition rate, and then use electo-optic modulator to modulate the intensity at 1 MHz. This method can potentially improve the signal to noise ratio due to pulse excitation of photoacoustic signal, and at the same time to achieve the high resolution of Doppler frequency shift due to the intensity modulation. With this method, we measured the moving speeds of various samples at the range of 0.1-1.6mm/s and obtained accurate results. The extra advantage of using supercontinnum laser pulses is that the spectral range can be chosen by using spectral filter thus to realize the multispectral measurement. To demonstrate this, we set the spectral filter working at five ranges at 500nm, 550nm, 600nm, 650nm, 700nm center wavelengths all with 100nm spectral width and measured different materials as moving targets fixed on the translation stage, including such as graphene thin layer, black tape, red and black dyed microspheres.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“On the other hand, the absorption spectrum in the flow state can be extracted from the Doppler-shifted power spectra [27,38,39].”
From Multiwavelength Photoacoustic Doppler Flowmetry of Living Microalgae Cells (2024) · cites this paper as [39]
Citations
Cites
Still being checked.
Cited by
Multiwavelength Photoacoustic Doppler Flowmetry of Living Microalgae Cells
Farooq, T., Wu, X., Yan, S., & Fang, H. (2024) · Biosensors · doi:10.3390/bios14080397 · Cited by 1
“On the other hand, the absorption spectrum in the flow state can be extracted from the Doppler-shifted power spectra [27,38,39].”
BackgroundSelf-citationWu, X., Farooq, T., Li, L., Yan, S., & Fang, H. (2023) · Tenth International Conference on Information Optics and Photonics · doi:10.1117/12.3005850 · Cited by 1
Self-citation
Metadata
- Authors
- Liu, Y., Fang, H., FAROOQ, T., & Yuan, X.
- Affiliations
- Shenzhen University (CN)
- Venue
- 2019 International Conference on Optical Instruments and Technology: Optical Sensors and Applications
- Publisher
- SPIE
- Published
- 2020-03-12
- Volume
- 11436
- OpenAlex
- W3011788999
- Cited by
- 2
- References
- 0
- Citations by year
- 2024: 1 · 2023: 1
- FWCI
- 0.45
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- International Conference on Optical Instruments and Technology: Optical Sensors and Applications (OIT) (publishedVersion)
- Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Photoacoustic and Ultrasonic Imaging
- Physical Sciences › Engineering › Mechanics of Materials › Thermography and Photoacoustic Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Measurement and Detection Methods
- Keywords
- supercontinuum laser, picosecond pulses, high repetition rate, intensity modulation, Doppler shift, signal-to-noise ratio, spectral filtering
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multispectral photoacoustic Doppler velocimetry with intensity modulated high repetition supercontinnum laser pulses. https://app.cochat.ai/papers/10.1117/12.2549505
- The paper
- Liu, Y., Fang, H., FAROOQ, T., & Yuan, X. (2020). Multispectral photoacoustic Doppler velocimetry with intensity modulated high repetition supercontinnum laser pulses. 2019 International Conference on Optical Instruments and Technology: Optical Sensors and Applications. https://doi.org/10.1117/12.2549505
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.