Application of near infrared spectroscopy to the evaluation of exercise performance and limitations in patients with heart failure
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Exercise performance in patients with heart failure is limited primarily due to a reduction in cardiac output. This results in skeletal muscle hypoperfusion. Near infrared spectroscopy provides a simple noninvasive method for assessing skeletal muscle oxygenation during exercise. In this paper we review the application of this technique to patients with heart failure and describe excessive limb and respiratory muscle oxygenation as compared to normal subjects. The potential of this technology for monitoring clinical improvement and therapeutic efficacy also is discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Recovery from exercise-induced desaturation in the quadriceps muscles of elite competitive rowers
Chance, B., Dait, M. T., Zhang, C., Hamaoka, T., & Hagerman, F. (1992) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1992.262.3.c766 · Cited by 528
Wilson, J. R., Mancini, D. M., McCully, K., Ferraro, N., Lanoce, V, & Chance, B. (1989) · Circulation · doi:10.1161/01.cir.80.6.1668 · Cited by 256 · cited 5×
“In animal studies it has been shown that the differential absorption between 760 and 800 nm of light (760 to 800 nm absorption) measured from the surface of the exercising canine gracilis muscle was correlated with venous hemoglobin oxygen saturation.(7) Other investigators have demonstrated that near infrared paramet…”
BackgroundMethodResultInfluentialSelf-citationBelardinelli, R., Barstow, T. J., Porszasz, J., & Wasserman, K. (1995) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00634377 · Cited by 213
Costes, F., Barthelemy, J. C., Feasson, L., Busso, T., Geyssant, A., & Denis, C. (1996) · Journal of Applied Physiology · doi:10.1152/jappl.1996.80.4.1345 · Cited by 101
Cited by
Grassi, B., Pogliaghi, S., Rampichini, S., Quaresima, V., Ferrari, M., Marconi, C., & Cerretelli, P. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00695.2002 · Cited by 429
Grassi, B., & Quaresima, V. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.9.091313 · Cited by 345
“It has been traditionally assumed that Hb is responsible for most of the overall NIRS signal.(51,52) The concept is supported by the observation of strong correlations, observed in different experimental models, between muscle oxygenation values obtained by NIRS and O2 saturation in venous blood (see below).”
BackgroundBlood lactate accumulation and muscle deoxygenation during incremental exercise
Grassi, B., Quaresima, V., Marconi, C., Ferrari, M., & Cerretelli, P. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.87.1.348 · Cited by 248
“tion of NIRS data have been recently reviewed (9, 13, 22).”
BackgroundMethodInfluential(2006) · PubMed · Cited by 89
Which common NIRS variable reflects muscle estimated lactate threshold most closely?
Wang, L., Yoshikawa, T., Hara, T., Nakao, H., Suzuki, T., & Fujimoto, S. (2006) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/h06-069 · Cited by 54
Metadata
- Authors
- Mancini, D.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 1997
- Volume
- 2
- Issue
- 1
- Pages
- 22
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2081168532
- Cited by
- 24
- References
- 4
- FWCI
- 3.38
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.