Study of an algorithm based on model experiments and diffusion theory for a portable tissue oximeter
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A portable tissue oximeter that uses light-emitting diodes and two-wavelength near infrared spectroscopy has been developed. The tissue oximeter is compact enough to be portable and it is therefore expected to make better use of the advantages of NIRS-based oximetry and to expand the scope of applications of monitoring tissue oxygen. The algorithm for this instrument was deduced through systematic experiments by varying blood volume and scattering intensity in a tissuelike phantom. The experimental results were compared with theoretical results obtained from diffusion theory. Experimentally determined coefficients of the algorithm were in close agreement with the theoretically derived coefficients. From evaluation tests of the algorithm applied to in vitro and in vivo measurements, it was confirmed that a good linear response to the concentration of oxygenated and deoxygenated blood can be obtained by this algorithm within a range of about a 50% change in concentration from an initial state.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Recovery from exercise-induced desaturation in the quadriceps muscles of elite competitive rowers
Chance, B., Dait, M. T., Zhang, C., Hamaoka, T., & Hagerman, F. (1992) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1992.262.3.c766 · Cited by 528
Self-citationWilson, J. R., Mancini, D. M., McCully, K., Ferraro, N., Lanoce, V, & Chance, B. (1989) · Circulation · doi:10.1161/01.cir.80.6.1668 · Cited by 256
Self-citation
Cited by
Ferrari, M., & Quaresima, V. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.03.049 · Cited by 2,274
“In 1994, Nakase and Shiga (Omron Institute of Life Science, Kyoto, Japan) developed, in collaboration with Chance, a single-channel portable oximeter for muscle studies (HEO-100, Omron Ltd. Inc., Japan) (Shiga et al., 1995, 1997).”
Functional near‐infrared optical imaging: Utility and limitations in human brain mapping
Hoshi, Y. (2003) · Psychophysiology · doi:10.1111/1469-8986.00053 · Cited by 532
Functional near-infrared spectroscopy: current status and future prospects
Hoshi, Y. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2804911 · Cited by 468
Grassi, B., Pogliaghi, S., Rampichini, S., Quaresima, V., Ferrari, M., Marconi, C., & Cerretelli, P. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00695.2002 · Cited by 429
Non-invasive NIR spectroscopy of human brain function during exercise
Perrey, S. (2008) · Methods · doi:10.1016/j.ymeth.2008.04.005 · Cited by 346
Metadata
- Authors
- Shiga, T.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 1997
- Volume
- 2
- Issue
- 2
- Pages
- 154
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2050978928
- Cited by
- 76
- References
- 2
- FWCI
- 3.40
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Study of an algorithm based on model experiments and diffusion theory for a portable tissue oximeter. https://app.cochat.ai/papers/10.1117/12.268963
- The paper
- Shiga, T. (1997). Study of an algorithm based on model experiments and diffusion theory for a portable tissue oximeter. Journal of Biomedical Optics. https://doi.org/10.1117/12.268963
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.