Abstract
We developed a three wavelength time-resolved spectroscopy system called the TRS-10 for use as a tissue oxygenation monitor. The TRS-10 achieved a higher data acquisition rate and a system miniaturization maintaining high sensitivity and time resolution. The TRS-10 consists of a three wavelength picosecond light pulser (PLP) with auto power control as a pulsed light source, a photomultiplier tube (PMT) having high speed and high sensitivity and miniaturized signal processing circuits for time-resolved measurement (CFD, TAC, A/D converter and histogram memory). The TRS-10 system was used to measure the time course of oxygen metabolism in a human forearm with a pneumatic cuff attached to occlude blood flow. Our system succeeded in accurately measuring concentrations of Oxy- (HbO2) and deoxyhemoglobin (Hb) in the human forearm based on diffusion theory by means of TRS data observation having an accumulation time of one second per point.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ferrari, M., & Quaresima, V. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.03.049 · Cited by 2,274
“In the same laboratory, a 3- wavelength TRS system for brain oxygenation measurements was also developed (Oda et al., 1999; Ohmae et al., 2006).”
Principles, Techniques, and Limitations of Near Infrared Spectroscopy
Ferrari, M., Mottola, L., & Quaresima, V. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-031 · Cited by 997
Understanding near infrared spectroscopy and its application to skeletal muscle research
Barstow, T. J. (2019) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00166.2018 · Cited by 470
Time domain functional NIRS imaging for human brain mapping
Torricelli, A., Contini, D., Pifferi, A., Caffini, M., Re, R., Zucchelli, L., & Spinelli, L. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.106 · Cited by 466
Tsunetsugu, Y., Park, B.-J., & Miyazaki, Y. (2010) · Environmental Health and Preventive Medicine · doi:10.1007/s12199-009-0091-z · Cited by 401
Metadata
- Authors
- Oda, M., Yamashita, Y., Nakano, T., Suzuki, A., Shimizu, K., Hirano, I., Shimomura, F., Ohmae, E., Suzuki, T., & Tsuchiya, Y.
- Venue
- SPIE Proceedings
- Publisher
- SPIE
- Published
- 1999-07-15
- Volume
- 3597
- Pages
- 611-617
- ISSN
- 0277-786X (ISSN-L)
- OpenAlex
- W2079369277
- Cited by
- 85
- References
- 0
- FWCI
- 11.07
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Near-infrared time-resolved spectroscopy system for tissue oxygenation monitor:. https://app.cochat.ai/papers/10.1117/12.356809
- The paper
- Oda, M., Yamashita, Y., Nakano, T., Suzuki, A., Shimizu, K., Hirano, I., Shimomura, F., Ohmae, E., Suzuki, T., & Tsuchiya, Y. (1999). Near-infrared time-resolved spectroscopy system for tissue oxygenation monitor:. SPIE Proceedings. https://doi.org/10.1117/12.356809
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.