The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Developments in synchrotron x-ray computed microtomography at the National Synchrotron Light Source:
Abstract
Last year, the X27A beamline at the National Synchrotron Light Source (NSLS) became dedicated solely to X-Ray Computed Microtomography (XCMT). This is a third-generation instrument capable of producing tomographic volumes of 1 - 2 micron resolution over a 2 - 3 mm field of view. Recent enhancements will be discussed. These have focused on two issues: the desire for real-time data acquisition and processing and the need for highly monochromatic beam (.1% energy bandpass). The latter will permit k-edge subtraction studies and will provide improved image contrast from below the Cr (6 keV) up to the Cs (36 keV) k-edge. A range of applications that benefit from these improvements will be discussed as well. These two goals are somewhat counterproductive, however; higher monochromaticity yields a lower flux forcing longer data acquisition times. To balance the two, a more efficient scintillator for X-ray conversion is being developed. Some testing of a prototype scintillator has been performed; preliminary results will be presented here. In the meantime, data reconstruction times have been reduced, and the entire tomographic acquisition, reconstruction and volume rendering process streamlined to make efficient use of synchrotron beam time. A Fast Filtered Back Transform (FFBT) reconstruction program recently developed helped to reduce the time to reconstruct a volume of 150 X 150 X 250 pixels3 (over 5 million voxels) from the raw camera data to 1.5 minutes on a dual R10,000 CPU. With these improvements, one can now obtain a 'quick look' of a small tomographic volume (approximately 106 voxels) in just over 15 minutes from the start of data acquisition.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Computerized Tomographic Imaging
Kak, A. C., & Slaney, M. (2001) · doi:10.1137/1.9780898719277 · Cited by 5,809
Prolate Spheroidal Wave Functions, Fourier Analysis and Uncertainty - I
Slepian, D., & Pollak, H. O. (1961) · Bell System Technical Journal · doi:10.1002/j.1538-7305.1961.tb03976.x · Cited by 2,492
Cited by
TomoPy: a framework for the analysis of synchrotron tomographic data
Gürsoy, D., De Carlo, F., Xiao, X., & Jacobsen, C. (2014) · Journal of Synchrotron Radiation · doi:10.1107/s1600577514013939 · Cited by 963
Regridding reconstruction algorithm for real-time tomographic imaging
Marone, F., & Stampanoni, M. (2012) · Journal of Synchrotron Radiation · doi:10.1107/s0909049512032864 · Cited by 441
Formation and evolution of carbonaceous asteroid Ryugu: Direct evidence from returned samples
Nakamura, T., Matsumoto, M., Amano, K., Enokido, Y., Zolensky, M. E., Mikouchi, T., Genda, H., Tanaka, S., Zolotov, M. Y., Kurosawa, K., et al. (2023) · Science · doi:10.1126/science.abn8671 · Cited by 345
PITRE: software for phase-sensitive X-ray image processing and tomography reconstruction
Chen, R.-C., Dreossi, D., Mancini, L., Menk, R., Rigon, L., Xiao, T.-Q., & Longo, R. (2012) · Journal of Synchrotron Radiation · doi:10.1107/s0909049512029731 · Cited by 279
Metadata
- Authors
- Dowd, B. A., Campbell, G. H., Marr, R. B., Nagarkar, V. V., Tipnis, S. V., Axe, L., & Siddons, D. P.
- Venue
- SPIE Proceedings
- Publisher
- SPIE
- Published
- 1999-09-22
- Volume
- 3772
- Pages
- 224-236
- ISSN
- 0277-786X (ISSN-L)
- OpenAlex
- W2069016924
- Cited by
- 232
- References
- 2
- FWCI
- 8.86
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Developments in synchrotron x-ray computed microtomography at the National Synchrotron Light Source:. https://app.cochat.ai/papers/10.1117/12.363725
- The paper
- Dowd, B. A., Campbell, G. H., Marr, R. B., Nagarkar, V. V., Tipnis, S. V., Axe, L., & Siddons, D. P. (1999). Developments in synchrotron x-ray computed microtomography at the National Synchrotron Light Source:. SPIE Proceedings. https://doi.org/10.1117/12.363725
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.