The DOI matches its Crossref record.
Enhanced semi-passive damping using continuous switching of a piezoelectric device on an inductor:
Abstract
The SSD technique proposed here addresses the problem of resonance damping on a mechanical structure. SSD stands for Synchronized Switch Damping. Apart from active techniques, passive ones consist in connecting a piezoelectric insert attached to the structure to a passive electric network in which the energy generated by the piezoelectric inserts is degraded. In the semi passive approach, the piezoelectric inserts are continuously switched from open circuit to short circuit synchronously to the structure motion. Due to this switching mechanism, a phase shift appears between the piezoelectric strain and the resulting voltage, thus creating energy dissipation. For the new technique proposed here, instead of discharging the piezoelectric inserts during a brief short circuit, they are connected on a small inductor, allowing the inversion of the voltage and then released to open circuit. In this case the voltage amplitude is optimized and is 90 degrees out of phase with the motion then enhancing the damping mechanism. The technique is applicable at any frequency without the need for a large tuned inductor, especially for low frequency applications. There is no need for external power supply unless for the low power circuitry of the switch device. The implementation of the switch drive with a very cheap micro-controller is described. Experimental results measured on cantilever beams made with different materials are proposed. Damping ability ranges from 6 dB on a very viscoelastic epoxy beam to nearly 20 dB on a steel beam. Harmonic excitation and transient results are both proposed and compared. Finally, an electromechanical model is proposed, giving an interpretation of the damping mechanism. Theoretical predictions are in good agreement with the experiments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Toward energy harvesting using active materials and conversion improvement by nonlinear processing
Guyomar, D., Badel, A., Lefeuvre, E., & Richard, C. (2005) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2005.1428041 · Cited by 1,049
Self-citationPyroelectric materials and devices for energy harvesting applications
Bowen, C. R., Taylor, J., LeBoulbar, E., Zabek, D., Chauhan, A., & Vaish, R. (2014) · Energy Environ. Sci. · doi:10.1039/c4ee01759e · Cited by 836
Vibration energy harvesting from random force and motion excitations
Tang, X., & Zuo, L. (2012) · Smart Materials and Structures · doi:10.1088/0964-1726/21/7/075025 · Cited by 72
Metadata
- Authors
- Richard, C., Guyomar, D., Audigier, D., & Bassaler, H.
- Venue
- SPIE Proceedings
- Publisher
- SPIE
- Published
- 2000-04-27
- Volume
- 3989
- Pages
- 288-299
- ISSN
- 0277-786X (ISSN-L)
- OpenAlex
- W2038049608
- Cited by
- 299
- References
- 0
- FWCI
- 7.44
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Enhanced semi-passive damping using continuous switching of a piezoelectric device on an inductor:. https://app.cochat.ai/papers/10.1117/12.384569
- The paper
- Richard, C., Guyomar, D., Audigier, D., & Bassaler, H. (2000). Enhanced semi-passive damping using continuous switching of a piezoelectric device on an inductor:. SPIE Proceedings. https://doi.org/10.1117/12.384569
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.