Functional imaging of muscle oxygenation using a 200-channel cw NIRS system:
The DOI matches its Crossref record.
Abstract
Functional imaging of muscle oxygenation using NIRS is a promising technique for evaluation of the heterogeneity of muscle function and diagnosis of peripheral vascular disease or muscle injury. We have developed a 200-channel imaging system that can measure the changes in oxygenation and blood volume of muscles and that covers wider area than previously reported systems. Our system consisted of 40 probes, a multiplexer for switching signals to and from the probes, and a personal computer for obtaining images. In each probe, one two-wavelength LED (770 and 830 nm) and five photodiodes were mounted on a flexible substrate. In order to eliminate the influence of a subcutaneous fat layer, a correction method, which we previously developed, was also used in imaging. Thus, quantitative changes in concentrations of oxy- and deoxy-hemoglobin were obtained. Temporal resolution was 1.5 s and spatial resolution was about 20 mm, depending on probe separations. Exercise tests (isometric contraction of 50% MVC) on the thigh with and without arterial occlusion were conducted, and changes in muscle oxygenation were imaged using the developed system. Results showed that the heterogeneity of deoxygenation and reoxygenation during exercise and recovery periods, respectively, were clearly observed. These results suggest that optical imaging of dynamic change in muscle oxygenation using NIRS would be useful not only for basic physiological studies but also for clinical applications with respect to muscle functions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2805437 · Cited by 329
Self-citationHamaoka, T., McCully, K. K., Niwayama, M., & Chance, B. (2011) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2011.0298 · Cited by 186
Self-citationIntelligent Systems for Muscle Tracking: A Review on Sensor‐Algorithm Synergy
Putcha, A., Nguyen, T., Smith, R., Choffin, R., & Bai, W. (2023) · Advanced Intelligent Systems · doi:10.1002/aisy.202200351 · Cited by 10
Metadata
- Authors
- Yamamoto, K., Niwayama, M., Kohata, D., Kudo, N., Hamaoka, T., Kime, R., & Katsumura, T.
- Venue
- SPIE Proceedings
- Publisher
- SPIE
- Published
- 2001-06-29
- Volume
- 4250
- Pages
- 142-152
- ISSN
- 0277-786X (ISSN-L)
- OpenAlex
- W1973060038
- Cited by
- 8
- References
- 0
- FWCI
- 3.63
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Functional imaging of muscle oxygenation using a 200-channel cw NIRS system:. https://app.cochat.ai/papers/10.1117/12.434486
- The paper
- Yamamoto, K., Niwayama, M., Kohata, D., Kudo, N., Hamaoka, T., Kime, R., & Katsumura, T. (2001). Functional imaging of muscle oxygenation using a 200-channel cw NIRS system:. SPIE Proceedings. https://doi.org/10.1117/12.434486
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.