The DOI matches its Crossref record.
New methods for CD measurements on photomasks using dark field optical microscopy:
Abstract
We present novel methods of dark field optical microscopy for CD measurements on photomasks in the sub lambda regime. Optical CD inspection systems usually suffer from limited resolution and from linear and nonlinear superposition of the light diffracted at both edges of a line structure (optical proximity effects). These disadvantages partly can be overcome using alternating grazing incidence illumination of the specimen, where the angle of incidence of the iilumination is perpendicular to the edges or grooves of the specimen. Especially for s-polarised light the diffraction efficiencies of the edges directed towards the illumination are at least an order of magnitude stronger than that of the averted edges. Thus an efficient suppression of optical proximity effects is achieved. Additionally a reduction of the widths of the diffraction limited images of structure edges due to a high pass characteristic of the optical image takes place. Both effects result in a significantly increased resolution power. We developed both a reflection mode (alternating grazing incidence dark field microscopy, AGID) and a transmission mode method (Frustrated internal total reflection microscopy, FIRM). Line width measurements on high quality photomasks will be presented. The experimental results will be compared with theoretical simulations and the applicability for sub lambda structures will be discussed
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“However, with darkfield illumination using a 100x oil objective (NA ¼ 1.4) the spatial resolution can be increased up to 232 nm and much greater contrast can be achieved (Bodermann et al. 2003).”
From Microplastics and nanoplastics science: collecting and characterizing airborne microplastics in fine particulate matter (2021) · cites this paper as Bodermann et al. 2003
Citations
Cited by
Sorted by citations
Rahman, L., Mallach, G., Kulka, R., & Halappanavar, S. (2021) · Nanotoxicology · doi:10.1080/17435390.2021.2018065 · Cited by 79
Metadata
- Authors
- Bodermann, B., Michaelis, W., Diener, A., & Mirande, W.
- Venue
- SPIE Proceedings
- Publisher
- SPIE
- Published
- 2003-06-02
- Volume
- 5148
- Pages
- 54-61
- ISSN
- 0277-786X
- Cited by
- 2
- References
- 0
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review