Cited by 2

The DOI matches its Crossref record.

New methods for CD measurements on photomasks using dark field optical microscopy:

Bodermann, Bernd, Michaelis, Winfried, Diener, Alexander, Mirande, Werner·2003·SPIE Proceedings

Abstract

We present novel methods of dark field optical microscopy for CD measurements on photomasks in the sub lambda regime. Optical CD inspection systems usually suffer from limited resolution and from linear and nonlinear superposition of the light diffracted at both edges of a line structure (optical proximity effects). These disadvantages partly can be overcome using alternating grazing incidence illumination of the specimen, where the angle of incidence of the iilumination is perpendicular to the edges or grooves of the specimen. Especially for s-polarised light the diffraction efficiencies of the edges directed towards the illumination are at least an order of magnitude stronger than that of the averted edges. Thus an efficient suppression of optical proximity effects is achieved. Additionally a reduction of the widths of the diffraction limited images of structure edges due to a high pass characteristic of the optical image takes place. Both effects result in a significantly increased resolution power. We developed both a reflection mode (alternating grazing incidence dark field microscopy, AGID) and a transmission mode method (Frustrated internal total reflection microscopy, FIRM). Line width measurements on high quality photomasks will be presented. The experimental results will be compared with theoretical simulations and the applicability for sub lambda structures will be discussed

Overview

Integrity signals

Registry

Crossref · 10.1117/12.514956

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cited by

Sorted by citations

Metadata

Authors
Bodermann, B., Michaelis, W., Diener, A., & Mirande, W.
Venue
SPIE Proceedings
Publisher
SPIE
Published
2003-06-02
Volume
5148
Pages
54-61
ISSN
0277-786X
Cited by
2
References
0

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review