The DOI matches its Crossref record.
Effects Of Subpixel Image Restoration On Digital Correlation Error Estimates
Abstract
Recently, a method has been developed that uses computer vision to determine the deformations of subsets of an object. Although the method has been used successfully in a variety of applications, to date there has been no critical assessment of the key parameters in the system and their effect on the accuracy of the measured deformations. The present work presents the results of initial studies of this system. The system components are modeled, and a representative intensity pattern is chosen and deformed by known amounts. Then, the effects of varying the various parameters in the model are analyzed numerically. The most significant parameters are found to be (1) the number of quantization levels in the digitization process (i.e., the number of bits in the A/D converter), (2) the ratio of the frequency of the signal to the frequency of the sampling, and (3) the form of the intensity interpolation function.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Gold Nanoparticles in Biology: Beyond Toxicity to Cellular Imaging
Murphy, C. J., Gole, A. M., Stone, J. W., Sisco, P. N., Alkilany, A. M., Goldsmith, E. C., & Baxter, S. C. (2008) · Accounts of Chemical Research · doi:10.1021/ar800035u · Cited by 1,807
Digital image correlation using Newton-Raphson method of partial differential correction
Bruck, H. A., McNeill, S. R., Sutton, M. A., & Peters, W. H. (1989) · Experimental Mechanics · doi:10.1007/bf02321405 · Cited by 1,456
Self-citationDigital volume correlation: Three-dimensional strain mapping using X-ray tomography
Bay, B. K., Smith, T. S., Fyhrie, D. P., & Saad, M. (1999) · Experimental Mechanics · doi:10.1007/bf02323555 · Cited by 941
Deep learning in optical metrology: a review
Zuo, C., Qian, J., Feng, S., Yin, W., Li, Y., Fan, P., Han, J., Qian, K., & Chen, Q. (2022) · Light: Science & Applications · doi:10.1038/s41377-022-00714-x · Cited by 711
Luo, P. F., Chao, Y. J., Sutton, M. A., & Peters, W. H. (1993) · Experimental Mechanics · doi:10.1007/bf02322488 · Cited by 628
Self-citationSubmicron deformation field measurements: Part 2. Improved digital image correlation
Vendroux, G., & Knauss, W. G. (1998) · Experimental Mechanics · doi:10.1007/bf02321649 · Cited by 516
Advances in Two-Dimensional and Three-Dimensional Computer Vision
Sutton, M. A., McNeill, S. R., Helm, J. D., & Chao, Y. J. (2000) · Topics in Applied Physics · doi:10.1007/3-540-48800-6_10 · Cited by 503
Self-citationRoux, S., & Hild, F. (2006) · International Journal of Fracture · doi:10.1007/s10704-006-6631-2 · Cited by 372
High-temperature deformation measurements using digital-image correlation
Lyons, J. S., Liu, J., & Sutton, M. A. (1996) · Experimental Mechanics · doi:10.1007/bf02328699 · Cited by 361
Self-citationRoux, S., Réthoré, J., & Hild, F. (2009) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/42/21/214004 · Cited by 273
In Situ Observation of Strains during Lithiation of a Graphite Electrode
Qi, Y., & Harris, S. J. (2010) · Journal of The Electrochemical Society · doi:10.1149/1.3377130 · Cited by 259
A review of optical NDT technologies
Zhu, Y.-K., Tian, G.-Y., Lu, R.-S., & Zhang, H. (2011) · Sensors · doi:10.3390/s110807773 · Cited by 228
Metadata
- Authors
- Sutton, M. A., McNeill, S. R., Jang, J., & Babai, M.
- Venue
- Optical Engineering
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 1988-10-01
- Volume
- 27
- Issue
- 10
- Pages
- 870-877
- ISSN
- 0091-3286 (ISSN-L)
- OpenAlex
- W2079705023
- Cited by
- 247
- References
- 0
- FWCI
- 2.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.