CoChat

Image Quality Measure Based On A Human Visual System Model

Saghri, John A., Cheatham, Patrick S., Habibi, Ali · 1989 · Optical Engineering
Cited by 101

The DOI matches its Crossref record.

Abstract

A preliminary image quality measure that takes into account two major sensitivities of the human visual system (HVS) is described. The sensitivities considered are background illumination level and spatial frequency sensitivities. Given a digitized monochrome image, the algorithm produces, among some other figures of merit, a plot of the information content (IC) versus the resolution in units of pixels. The IC is defined here as the sum of the weighted spectral components at an arbitrary specified resolution. The HVS normalization is done by first intensity remapping the image by a monotonically increasing function representing the background illumination level sensitivity, followed by a spectral filtering to compensate for the spatial frequency sensitivity. The developed quality measure is conveniently parameterized and interactive. It allows experimentation with numerous parameters of the HVS model to determine the optimum set for which the highest correlation with subjective evaluations can be achieved. The preliminary results are promising.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1117/12.7977038

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Saghri, J. A., Cheatham, P. S., & Habibi, A.
Venue
Optical Engineering
Published
1989-07-01
Volume
28
Issue
7
Pages
813-818
ISSN
0091-3286 (ISSN-L)
OpenAlex
W2044770391
Cited by
101
References
0
FWCI
1.09
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.