CoChat

Quantitative computerized analysis of diffuse lung disease in high‐resolution computed tomography

Uchiyama, Yoshikazu, Katsuragawa, Shigehiko, Abe, Hiroyuki, Shiraishi, Junji, Li, Feng, Li, Qiang, Zhang, Chao‐Tong, Suzuki, Kenji, Doi, Kunio · 2003 · Medical Physics
Cited by 157

The DOI matches its Crossref record.

Abstract

An automated computerized scheme has been developed for the detection and characterization of diffuse lung diseases on high‐resolution computed tomography (HRCT) images. Our database consisted of 315 HRCT images selected from 105 patients, which included normal and abnormal slices related to six different patterns, i.e., ground‐glass opacities, reticular and linear opacities, nodular opacities, honeycombing, emphysematous change, and consolidation. The areas that included specific diffuse patterns in 315 HRCT images were marked by three radiologists independently on the CRT monitor in the same manner as they commonly describe in their radiologic reports. The areas with a specific pattern, which three radiologists marked independently and consistently as the same patterns, were used as “gold standard” for specific abnormal opacities in this study. The lungs were first segmented from the background in each slice by use of a morphological filter and a thresholding technique, and then divided into many contiguous regions of interest (ROIs) with a matrix. Six physical measures which were determined in each ROI included the mean and the standard deviation of the CT value, air density components, nodular components, line components, and multilocular components. Artificial neural networks (ANNs) were employed for distinguishing between seven different patterns which included normals and six patterns associated with diffuse lung disease. The sensitivity of this computerized method for a detection of the six abnormal patterns in each ROI was 99.2% (122/123) for ground‐glass opacities, 100% (15/15) for reticular and linear opacities, 88.0% (132/150) for nodular opacities, 100% (98/98) for honeycombing, 95.8% (369/385) for emphysematous change, and 100% (43/43) for consolidation. The specificity in detecting a normal ROI was 88.1% (940/1067). This computerized method may be useful in assisting radiologists in their assessment of diffuse lung disease in HRCT images.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1118/1.1597431

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 157

Metadata

Authors
Uchiyama, Y., Katsuragawa, S., Abe, H., Shiraishi, J., Li, F., Li, Q., Zhang, C., Suzuki, K., & Doi, K.
Venue
Medical Physics
Publisher
Wiley
Published
2003-08-22
Volume
30
Issue
9
Pages
2440-2454
ISSN
  • 0094-2405 (ISSN-L)
  • 2473-4209
OpenAlex
W2085206647
Cited by
157
References
0
FWCI
3.88
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Quantitative computerized analysis of diffuse lung disease in high‐resolution computed tomography. https://app.cochat.ai/papers/10.1118/1.1597431
The paper
Uchiyama, Y., Katsuragawa, S., Abe, H., Shiraishi, J., Li, F., Li, Q., Zhang, C., Suzuki, K., & Doi, K. (2003). Quantitative computerized analysis of diffuse lung disease in high‐resolution computed tomography. Medical Physics. https://doi.org/10.1118/1.1597431

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.