The DOI matches its Crossref record.
Computerized interpretation of breast MRI: Investigation of enhancement‐variance dynamics
Abstract
The advantages of breast MRI using contrast agent Gd‐DTPA in the diagnosis of breast cancer have been well established. The variation of interpretation criteria and absence of interpretation guidelines, however, is a major obstacle for applications of MRI in the routine clinical practice of breast imaging. Our study aims to increase the objectivity and reproducibility of breast MRI interpretation by developing an automated interpretation approach for ultimate use in computer‐aided diagnosis. The database in this study contains 121 cases: 77 malignant and 44 benign masses as revealed by biopsy. Images were obtained using a T1‐weighted 3D spoiled gradient echo sequence. After the acquisition of the precontrast series, Gd‐DTPA contrast agent was injected intravenously by power injection with a dose of 0.2 mmol/kg. Five postcontrast series were then taken with a time interval of 60 s. Each series contained 64 coronal slices with a matrix of and an in‐plane resolution of Slice thickness ranged from 2 to 3 mm depending on breast size. The lesions were delineated by an experienced radiologist as well as independently by computer using an automatic volume‐growing algorithm. Fourteen features that were extracted automatically from the lesions could be grouped into three categories based on (I) morphology, (II) enhancement kinetics, and (III) time course of enhancement‐variation over the lesion. A stepwise feature selection procedure was employed to select an effective subset of features, which were then combined by linear discriminant analysis (LDA) into a discriminant score, related to the likelihood of malignancy. The classification performances of individual features and the combined discriminant score were evaluated with receiver operating characteristic (ROC) analysis. With the radiologist‐delineated lesion contours, stepwise feature selection yielded four features and an value of 0.80 for the LDA in leave‐one‐out cross‐validation testing. With the computer‐segmented lesion volumes, it yielded six features and an value of 0.86 for the LDA in the leave‐one‐out testing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Artificial intelligence in cancer imaging: Clinical challenges and applications
Bi, W. L., Hosny, A., Schabath, M. B., Giger, M. L., Birkbak, N. J., Mehrtash, A., Allison, T., Arnaout, O., Abbosh, C., Dunn, I. F., et al. (2019) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.21552 · Cited by 1,846
Self-citationGiger (2018) · doi:10.1016/j.jacr.2017.12.028 · Cited by 634
Li, H., Zhu, Y., Burnside, E. S., Drukker, K., Hoadley, K. A., Fan, C., Conzen, S. D., Whitman, G. J., Sutton, E. J., Net, J. M., et al. (2016) · Radiology · doi:10.1148/radiol.2016152110 · Cited by 461
Self-citationYankeelov, T., & Gore, J. (2007) · Current Medical Imaging Reviews · doi:10.2174/157340507780619179 · Cited by 398
Li, H., Zhu, Y., Burnside, E. S., Huang, E., Drukker, K., Hoadley, K. A., Fan, C., Conzen, S. D., Zuley, M., Net, J. M., et al. (2016) · npj Breast Cancer · doi:10.1038/npjbcancer.2016.12 · Cited by 364
Self-citation
Metadata
- Authors
- Chen, W., Giger, M. L., Lan, L., & Bick, U.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2004-04-08
- Volume
- 31
- Issue
- 5
- Pages
- 1076-1082
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2059165786
- Cited by
- 186
- References
- 0
- FWCI
- 5.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Computerized interpretation of breast MRI: Investigation of enhancement‐variance dynamics. https://app.cochat.ai/papers/10.1118/1.1695652
- The paper
- Chen, W., Giger, M. L., Lan, L., & Bick, U. (2004). Computerized interpretation of breast MRI: Investigation of enhancement‐variance dynamics. Medical Physics. https://doi.org/10.1118/1.1695652
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.