Multifractality, sample entropy, and wavelet analyses for age-related changes in the peripheral cardiovascular system: Preliminary results
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Using signal processing measures we evaluate the effect of aging on the peripheral cardiovascular system. Laser Doppler flowmetry (LDF) signals, reflecting the microvascular perfusion, are recorded on the forearm of 27 healthy subjects between 20-30, 40-50, or 60-70 years old. Wavelet-based representations, Hölder exponents, and sample entropy values are computed for each time series. The results indicate a possible modification of the peripheral cardiovascular system with aging. Thus, the endothelial-related metabolic activity decreases, but not significantly, with aging. Furthermore, LDF signals are more monofractal for elderly subjects than for young people for whom LDF signals are weakly multifractal: the average range of Holder exponents computed with a parametric generalized quadratic variation based estimation method is 0.13 for subjects between 20 and 30 years old and 0.06 for subjects between 60 and 70 years old. Moreover, the average mean sample entropy value of LDF signals slightly decreases with age: it is 1.34 for subjects between 20 and 30 years old and 1.19 for subjects between 60 and 70 years old. Our results could assist in gaining knowledge on the relationship between microvascular system status and age and could also lead to a more accurate age-related nonlinear modeling.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Determining Lyapunov exponents from a time series
Wolf, A., Swift, J. B., Swinney, H. L., & Vastano, J. A. (1985) · Physica D: Nonlinear Phenomena · doi:10.1016/0167-2789(85)90011-9 · Cited by 9,499
Physiological time-series analysis using approximate entropy and sample entropy
Richman, J. S., & Moorman, J. R. (2000) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.2000.278.6.h2039 · Cited by 7,880
Approximate entropy as a measure of system complexity.
Pincus, S. M. (1991) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.88.6.2297 · Cited by 5,811
Cited by
Non‐invasive Assessment of Skin Microvascular Function in Humans: An Insight Into Methods
ROUSTIT, M., & CRACOWSKI, J. (2012) · Microcirculation · doi:10.1111/j.1549-8719.2011.00129.x · Cited by 373
Multiscale Analysis of Intensive Longitudinal Biomedical Signals and Its Clinical Applications
Nakamura, T., Kiyono, K., Wendt, H., Abry, P., & Yamamoto, Y. (2016) · Proceedings of the IEEE · doi:10.1109/jproc.2015.2491979 · Cited by 64
“Recent methodological developments in multifractal analysis are expected to expand its potential applications to HRV analysis [83]–[85], [91], [92].”
BackgroundNemati, S., Edwards, B. A., Lee, J., Pittman-Polletta, B., Butler, J. P., & Malhotra, A. (2013) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2013.06.016 · Cited by 58
“Notably, a conditional variant of entropy known as sample entropy has been widely used to assess the complexity of HR (Humeau et al., 2008; Lake et al., 2002; Moorman et al., 2011; Vaillancourt et al., 2004).”
Objective evaluation of speech dysfluencies using wavelet packet transform with sample entropy
Hariharan, M., Fook, C. Y., Sindhu, R., Adom, A. H., & Yaacob, S. (2013) · Digital Signal Processing · doi:10.1016/j.dsp.2012.12.003 · Cited by 26
Metadata
- Authors
- Humeau, A., Chapeau-Blondeau, F., Rousseau, D., Rousseau, P., Trzepizur, W., & Abraham, P.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2008-01-29
- Volume
- 35
- Issue
- 2
- Pages
- 717-723
- ISSN
- 0094-2405 (ISSN-L)
- OpenAlex
- W2102950645
- Cited by
- 65
- References
- 3
- FWCI
- 4.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.