Magnetic nanoparticle temperature estimation
Open accessAbstract
The authors present a method of measuring the temperature of magnetic nanoparticles that can be adapted to provide in vivo temperature maps. Many of the minimally invasive therapies that promise to reduce health care costs and improve patient outcomes heat tissue to very specific temperatures to be effective. Measurements are required because physiological cooling, primarily blood flow, makes the temperature difficult to predict a priori. The ratio of the fifth and third harmonics of the magnetization generated by magnetic nanoparticles in a sinusoidal field is used to generate a calibration curve and to subsequently estimate the temperature. The calibration curve is obtained by varying the amplitude of the sinusoidal field. The temperature can then be estimated from any subsequent measurement of the ratio. The accuracy was 0.3 °K between 20 and using the current apparatus and half‐second measurements. The method is independent of nanoparticle concentration and nanoparticle size distribution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fundamentals and advances in magnetic hyperthermia
Périgo, E. A., Hemery, G., Sandre, O., Ortega, D., Garaio, E., Plazaola, F., & Teran, F. J. (2015) · Applied Physics Reviews · doi:10.1063/1.4935688 · Cited by 836
Tay, Z. W., Chandrasekharan, P., Chiu-Lam, A., Hensley, D. W., Dhavalikar, R., Zhou, X. Y., Yu, E. Y., Goodwill, P. W., Zheng, B., Rinaldi, C., et al. (2018) · ACS Nano · doi:10.1021/acsnano.8b00893 · Cited by 459
Rezaei, B., Yari, P., Sanders, S. M., Wang, H., Chugh, V. K., Liang, S., Mostufa, S., Xu, K., Wang, J., Gómez‐Pastora, J., et al. (2024) · Small · doi:10.1002/smll.202304848 · Cited by 366
Magnetic Particle Imaging (MPI) for NMR and MRI researchers
Saritas, E. U., Goodwill, P. W., Croft, L. R., Konkle, J. J., Lu, K., Zheng, B., & Conolly, S. M. (2013) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2012.11.029 · Cited by 307
Metadata
- Authors
- Weaver, J. B., Rauwerdink, A. M., & Hansen, E. W.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2009-04-22
- Volume
- 36
- Issue
- 5
- Pages
- 1822-1829
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2033359620
- Cited by
- 209
- References
- 0
- FWCI
- 4.27
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Magnetic nanoparticle temperature estimation. https://app.cochat.ai/papers/10.1118/1.3106342
- The paper
- Weaver, J. B., Rauwerdink, A. M., & Hansen, E. W. (2009). Magnetic nanoparticle temperature estimation. Medical Physics. https://doi.org/10.1118/1.3106342
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.