Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 195

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

The evolution of brachytherapy treatment planning

Open access
Rivard, Mark J., Venselaar, Jack L. M., Beaulieu, Luc · 2009 · Medical Physics

Abstract

Brachytherapy is a mature treatment modality that has benefited from technological advances. Treatment planning has advanced from simple lookup tables to complex, computer‐based dose‐calculation algorithms. The current approach is based on the AAPM TG‐43 formalism with recent advances in acquiring single‐source dose distributions. However, this formalism has clinically relevant limitations for calculating patient dose. Dose‐calculation algorithms are being developed based on Monte Carlo methods, collapsed cone, and solving the linear Boltzmann transport equation. In addition to improved dose‐calculation tools, planning systems and brachytherapy treatment planning will account for material heterogeneities, scatter conditions, radiobiology, and image guidance. The AAPM, ESTRO, and other professional societies are working to coordinate clinical integration of these advancements. This Vision 20/20 article provides insight into these endeavors.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1118/1.3125136

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • Geant4—a simulation toolkit

    Agostinelli, S., Allison, J., Amako, K., Apostolakis, J., Araujo, H., Arce, P., Asai, M., Axen, D., Banerjee, S., Barrand, G., et al. (2003) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/s0168-9002(03)01368-8 · Cited by 25,106

  • Geant4 developments and applications

    Allison, J., Amako, K., Apostolakis, J., Araujo, H., Arce Dubois, P., Asai, M., Barrand, G., Capra, R., Chauvie, S., Chytracek, R., et al. (2006) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2006.869826 · Cited by 6,946

Show all 2 references

Cited by

See all 195

Metadata

Authors
Rivard, M. J., Venselaar, J. L. M., & Beaulieu, L.
Venue
Medical Physics
Publisher
Wiley
Published
2009-05-08
Volume
36
Issue
6Part1
Pages
2136-2153
ISSN
  • 0094-2405 (ISSN-L)
  • 2473-4209
OpenAlex
W2082186719
Cited by
195
References
2
FWCI
15.01
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The evolution of brachytherapy treatment planning. https://app.cochat.ai/papers/10.1118/1.3125136
The paper
Rivard, M. J., Venselaar, J. L. M., & Beaulieu, L. (2009). The evolution of brachytherapy treatment planning. Medical Physics. https://doi.org/10.1118/1.3125136

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.