Image-based dual energy CT using optimized precorrection functions: A practical new approach of material decomposition in image domain
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Dual energy CT (DECT) measures the object of interest using two different x-ray spectra in order to provide energy-selective CT images or in order to get the material decomposition of the object. Today, two decomposition techniques are known. Image-based DECT uses linear combinations of reconstructed images to get an image that contains material-selective DECT information. Rawdata-based DECT correctly treats the available information by passing the rawdata through a decomposition function that uses information from both rawdata sets to create DECT specific (e.g., material-selective) rawdata. Then the image reconstruction yields material-selective images. Rawdata-based image decomposition generally obtains better image quality; however, it needs matched rawdata sets. This means that physically the same lines need to be measured for each spectrum. In today's CT scanners, this is not the case. The authors propose a new image-based method to combine mismatched rawdata sets for DECT information. The method allows for implementation in a scanner's rawdata precorrection pipeline or may be used in image domain. They compare the ability of the three methods (image-based standard method, proposed method, and rawdata-based standard method) to perform material decomposition and to provide monochromatic images. Thereby they use typical clinical and preclinical scanner arrangements including circular cone-beam CT and spiral CT. The proposed method is found to perform better than the image-based standard method and is inferior to the rawdata-based method. However, the proposed method can be used with the frequent case of mismatched data sets that exclude rawdata-based methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Energy-selective reconstructions in X-ray computerised tomography
Alvarez, R. E., & Macovski, A. (1976) · Physics in Medicine & Biology · doi:10.1088/0031-9155/21/5/002 · Cited by 2,013
Evaluation of a prototype dual‐energy computed tomographic apparatus. I. Phantom studies
Kalender, W. A., Perman, W. H., Vetter, J. R., & Klotz, E. (1986) · Medical Physics · doi:10.1118/1.595958 · Cited by 451
Vetter, J. R., Perman, W. H., Kalender, W. A., Mazess, R. B., & Holden, J. E. (1986) · Medical Physics · doi:10.1118/1.595951 · Cited by 138
A beam-hardening correction using dual-energy computed tomography
Coleman, A. J., & Sinclair, M. (1985) · Physics in Medicine and Biology · doi:10.1088/0031-9155/30/11/007 · Cited by 87 · cited 2×
“We will refer to the new method as the Coleman method since he used a similar decomposition in reference [3], but without realizing that an implementation in image domain was possible.”
Method
Cited by
Iterative image‐domain decomposition for dual‐energy CT
Niu, T., Dong, X., Petrongolo, M., & Zhu, L. (2014) · Medical Physics · doi:10.1118/1.4866386 · Cited by 159
HANDSCHUH, S., BEISSER, C. J., RUTHENSTEINER, B., & METSCHER, B. D. (2017) · Journal of Microscopy · doi:10.1111/jmi.12543 · Cited by 48
“Other decomposition methods using iterative dual-energy reconstruction methods and tools for prereconstruction material decomposition (Maass et al., 2009; Depypere et al., 2011; Magnusson et al., 2011; Endrizzi et al., 2012) have been shown to improve the quality of material decomposition significantly and to eliminat…”
Metadata
- Authors
- Maaß, C., Baer, M., & Kachelrieß, M.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2009-07-24
- Volume
- 36
- Issue
- 8
- Pages
- 3818-3829
- ISSN
- 0094-2405 (ISSN-L)
- OpenAlex
- W2059360236
- Cited by
- 194
- References
- 4
- FWCI
- 3.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Image-based dual energy CT using optimized precorrection functions: A practical new approach of material decomposition in image domain. https://app.cochat.ai/papers/10.1118/1.3157235
- The paper
- Maaß, C., Baer, M., & Kachelrieß, M. (2009). Image-based dual energy CT using optimized precorrection functions: A practical new approach of material decomposition in image domain. Medical Physics. https://doi.org/10.1118/1.3157235
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.