The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A novel fuzzy C‐means algorithm for unsupervised heterogeneous tumor quantification in PET
Open accessAbstract
Purpose: Accurate and robust image segmentation was identified as one of the most challenging issues facing PET quantification in oncological imaging. This difficulty is compounded by the low spatial resolution and high noise characteristics of PET images. The fuzzy C‐means (FCM) clustering algorithm was largely used in various medical image segmentation approaches. However, the algorithm is sensitive to both noise and intensity heterogeneity since it does not take into account spatial contextual information. Methods: To overcome this limitation, a new fuzzy segmentation technique adapted to typical noisy and low resolution oncological PET data is proposed. PET images smoothed using a nonlinear anisotropic diffusion filter are added as a second input to the proposed FCM algorithm to incorporate spatial information (FCM‐S). In addition, a methodology was developed to integrate the à trous wavelet transform in the standard FCM algorithm (FCM‐SW) to allow handling of heterogeneous lesions’ uptake. The algorithm was applied to the simulated data of the NCAT phantom, incorporating heterogeneous lesions in the lung and clinical PET/CT images of 21 patients presenting with histologically proven nonsmall‐cell lung cancer (NSCLC) and 7 patients presenting with laryngeal squamous cell carcinoma (LSCC) to assess its performance for segmenting tumors with arbitrary size, shape, and tracer uptake. For NSCLC patients, the maximal tumor diameters measured from the macroscopic examination of the surgical specimen served as the ground truth for comparison with the maximum diameter estimated by the segmentation technique, whereas for LSCC patients, the 3D macroscopic tumor volume was considered as the ground truth for comparison with the corresponding PET‐based volume. The proposed algorithm was also compared to the classical FCM segmentation technique. Results: There is a good correlation between the actual maximal diameter of primary NSCLC tumors estimated using the proposed PET segmentation procedure and those measured from the macroscopic examination, and the regression line agreed well with the line of identity for the group analysis of the clinical data. The standard FCM algorithm seems to underestimate actual maximal diameters of the clinical data, resulting in a mean error of −4.6 mm (relative error of) for all data sets. The mean error of maximal diameter estimation was reduced to 0.1 mm using the proposed FCM‐SW algorithm. Likewise, the mean relative error on the estimated volume for LSCC patients was reduced from for FCM to using the proposed FCM‐SW technique. Conclusions: A novel unsupervised PET image segmentation technique that allows the quantification of lesions in the presence of heterogeneity of tracer uptake was developed and evaluated. The technique is being further refined and assessed in clinical setting to delineate treatment volumes for the purpose of PET‐guided radiation therapy treatment planning but could find other applications in clinical oncology such as the assessment of response to treatment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Computational Approach to Edge Detection
Canny, J. (1986) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1986.4767851 · Cited by 30,004
Cited by
A review on segmentation of positron emission tomography images
Foster, B., Bagci, U., Mansoor, A., Xu, Z., & Mollura, D. J. (2014) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2014.04.014 · Cited by 370
Zaidi, H., & El Naqa, I. (2010) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-010-1423-3 · Cited by 366
Self-citationPositron Emission Tomography (PET) in Oncology
Gallamini, A., Zwarthoed, C., & Borra, A. (2014) · Cancers · doi:10.3390/cancers6041821 · Cited by 312
Rogasch, J. M., Hofheinz, F., Lougovski, A., Furth, C., Ruf, J., Großer, O. S., Mohnike, K., Hass, P., Walke, M., Amthauer, H., et al. (2014) · EJNMMI Physics · doi:10.1186/2197-7364-1-12 · Cited by 53
Metadata
- Authors
- Belhassen, S., & Zaidi, H.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2010-02-25
- Volume
- 37
- Issue
- 3
- Pages
- 1309-1324
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2043408616
- Cited by
- 190
- References
- 1
- FWCI
- 20.64
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.