The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Comparison of GEANT4 very low energy cross section models with experimental data in water
Abstract
Purpose: The GEANT4 general‐purpose Monte Carlo simulation toolkit is able to simulate physical interaction processes of electrons, hydrogen and helium atoms with charge states (, ) and (, , ), respectively, in liquid water, the main component of biological systems, down to the electron volt regime and the submicrometer scale, providing GEANT4 users with the so‐called “GEANT4‐DNA” physics models suitable for microdosimetry simulation applications. The corresponding software has been recently re‐engineered in order to provide GEANT4 users with a coherent and unique approach to the simulation of electromagnetic interactions within the GEANT4 toolkit framework (since GEANT4 version 9.3 beta). This work presents a quantitative comparison of these physics models with a collection of experimental data in water collected from the literature. Methods: An evaluation of the closeness between the total and differential cross section models available in the GEANT4 toolkit for microdosimetry and experimental reference data is performed using a dedicated statistical toolkit that includes the Kolmogorov–Smirnov statistical test. The authors used experimental data acquired in water vapor as direct measurements in the liquid phase are not yet available in the literature. Comparisons with several recommendations are also presented. Results: The authors have assessed the compatibility of experimental data with GEANT4 microdosimetry models by means of quantitative methods. The results show that microdosimetric measurements in liquid water are necessary to assess quantitatively the validity of the software implementation for the liquid water phase. Nevertheless, a comparison with existing experimental data in water vapor provides a qualitative appreciation of the plausibility of the simulation models. The existing reference data themselves should undergo a critical interpretation and selection, as some of the series exhibit significant deviations from each other. Conclusions: The GEANT4‐DNA physics models available in the GEANT4 toolkit have been compared in this article to available experimental data in the water vapor phase as well as to several published recommendations on the mass stopping power. These models represent a first step in the extension of the GEANT4 Monte Carlo toolkit to the simulation of biological effects of ionizing radiation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Agostinelli, S., Allison, J., Amako, K., Apostolakis, J., Araujo, H., Arce, P., Asai, M., Axen, D., Banerjee, S., Barrand, G., et al. (2003) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/s0168-9002(03)01368-8 · Cited by 25,106
Self-citationThe unified Modeling Language User Guide
Glasson, G. (1999) · Linux journal · doi:10.5555/327966.328423 · Cited by 3,333
EDF Statistics for Goodness of Fit and Some Comparisons
Stephens, M. A. (1974) · Journal of the American Statistical Association · doi:10.1080/01621459.1974.10480196 · Cited by 3,166
INCERTI, S., BALDACCHINO, G., BERNAL, M., CAPRA, R., CHAMPION, C., FRANCIS, Z., GUÈYE, P., MANTERO, A., MASCIALINO, B., MORETTO, P., et al. (2010) · International Journal of Modeling, Simulation, and Scientific Computing · doi:10.1142/s1793962310000122 · Cited by 538
Self-citationCollective oscillation in liquid water
Heller, J. M., Hamm, R. N., Birkhoff, R. D., & Painter, L. R. (1974) · The Journal of Chemical Physics · doi:10.1063/1.1681563 · Cited by 327
Electron inelastic-scattering cross sections in liquid water
Dingfelder, M., Hantke, D., Inokuti, M., & Paretzke, H. G. (1998) · Radiation Physics and Chemistry · doi:10.1016/s0969-806x(97)00317-4 · Cited by 302
Inelastic-collision cross sections of liquid water for interactions of energetic protons
Dingfelder, M., Inokuti, M., & Paretzke, H. G. (2000) · Radiation Physics and Chemistry · doi:10.1016/s0969-806x(00)00263-2 · Cited by 195
Schutten, J., de Heer, F. J., Moustafa, H. R., Boerboom, A. J. H., & Kistemaker, J. (1966) · The Journal of Chemical Physics · doi:10.1063/1.1726553 · Cited by 187
Uehara, S., Nikjoo, H., & GOODHEAD, D. T. (1993) · Physics in Medicine and Biology · doi:10.1088/0031-9155/38/12/010 · Cited by 167
Straub, H. C., Lindsay, B. G., Smith, K. A., & Stebbings, R. F. (1998) · The Journal of Chemical Physics · doi:10.1063/1.475367 · Cited by 158
Cited by
Allison, J., Amako, K., Apostolakis, J., Arce, P., Asai, M., Aso, T., Bagli, E., Bagulya, A., Banerjee, S., Barrand, G., et al. (2016) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/j.nima.2016.06.125 · Cited by 4,194
Self-citationSarrut, D., Bardiès, M., Boussion, N., Freud, N., Jan, S., Létang, J.-M., Loudos, G., Maigne, L., Marcatili, S., Mauxion, T., et al. (2014) · Medical Physics · doi:10.1118/1.4871617 · Cited by 573
Bernal, M. A., Bordage, M. C., Brown, J. M. C., Davídková, M., Delage, E., El Bitar, Z., Enger, S. A., Francis, Z., Guatelli, S., Ivanchenko, V. N., et al. (2015) · Physica Medica · doi:10.1016/j.ejmp.2015.10.087 · Cited by 536
Self-citationIncerti, S., Kyriakou, I., Bernal, M. A., Bordage, M. C., Francis, Z., Guatelli, S., Ivanchenko, V., Karamitros, M., Lampe, N., Lee, S. B., et al. (2018) · Medical Physics · doi:10.1002/mp.13048 · Cited by 439
Self-citationRadiation track, DNA damage and response—a review
Nikjoo, H., Emfietzoglou, D., Liamsuwan, T., Taleei, R., Liljequist, D., & Uehara, S. (2016) · Reports on Progress in Physics · doi:10.1088/0034-4885/79/11/116601 · Cited by 330
Metadata
- Authors
- Incerti, S., Ivanchenko, A., Karamitros, M., Mantero, A., Moretto, P., Tran, H. N., Mascialino, B., Champion, C., Ivanchenko, V. N., Bernal, M. A., Francis, Z., Villagrasa, C., Baldacchino, G., Guèye, P., Capra, R., Nieminen, P., & Zacharatou, C.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2010-08-17
- Volume
- 37
- Issue
- 9
- Pages
- 4692-4708
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2026812997
- Cited by
- 514
- References
- 34
- FWCI
- 11.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of GEANT4 very low energy cross section models with experimental data in water. https://app.cochat.ai/papers/10.1118/1.3476457
- The paper
- Incerti, S., Ivanchenko, A., Karamitros, M., Mantero, A., Moretto, P., Tran, H. N., Mascialino, B., Champion, C., Ivanchenko, V. N., Bernal, M. A., Francis, Z., Villagrasa, C., Baldacchino, G., Guèye, P., Capra, R., Nieminen, P., & Zacharatou, C. (2010). Comparison of GEANT4 very low energy cross section models with experimental data in water. Medical Physics. https://doi.org/10.1118/1.3476457
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.