The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
A planning quality evaluation tool for prostate adaptive IMRT based on machine learning
Open accessAbstract
Purpose: To ensure plan quality for adaptive IMRT of the prostate, we developed a quantitative evaluation tool using a machine learning approach. This tool generates dose volume histograms (DVHs) of organs‐at‐risk (OARs) based on prior plans as a reference, to be compared with the adaptive plan derived from fluence map deformation. Methods: Under the same configuration using seven‐field 15 MV photon beams, DVHs of OARs (bladder and rectum) were estimated based on anatomical information of the patient and a model learned from a database of high quality prior plans. In this study, the anatomical information was characterized by the organ volumes and distance‐to‐target histogram (DTH). The database consists of 198 high quality prostate plans and was validated with 14 cases outside the training pool. Principal component analysis (PCA) was applied to DVHs and DTHs to quantify their salient features. Then, support vector regression (SVR) was implemented to establish the correlation between the features of the DVH and the anatomical information. Results: DVH/DTH curves could be characterized sufficiently just using only two or three truncated principal components, thus, patient anatomical information was quantified with reduced numbers of variables. The evaluation of the model using the test data set demonstrated its accuracy in prediction and effectiveness in improving ART planning quality. Conclusions: An adaptive IMRT plan quality evaluation tool based on machine learning has been developed, which estimates OAR sparing and provides reference in evaluating ART.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cortes, C., & Vapnik, V. (1995) · Machine Learning · doi:10.1007/bf00994018 · Cited by 59,421
A tutorial on support vector regression
Smola, A. J., & Schölkopf, B. (2004) · Statistics and Computing · doi:10.1023/b:stco.0000035301.49549.88 · Cited by 13,387
Support Vector Regression Machines
Drucker, H., Burges, C. J. C., Kaufman, L., Smola, A. J., & Vapnik, V. N. (1996) · Cited by 4,658
Yan, D., Vicini, F., Wong, J., & Martinez, A. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/1/008 · Cited by 761
On a Kernel-Based Method for Pattern Recognition, Regression, Approximation, and Operator Inversion
Smola, A. J., & Schölkopf, B. (1998) · Algorithmica · doi:10.1007/pl00013831 · Cited by 298
Mohan, R., Zhang, X., Wang, H., Kang, Y., Wang, X., Liu, H., Ang, K. K., Kuban, D., & Dong, L. (2005) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2004.11.033 · Cited by 227
Adapting inverse planning to patient and organ geometrical variation: algorithm and implementation
Birkner, M., Yan, D., Alber, M. L., Liang, J., & Nüsslin, F. (2003) · Medical Physics · doi:10.1118/1.1610751 · Cited by 135
Dose volume histogram analysis of liver radiation tolerance
Austin-Seymour, M., Chen, G. T. Y., Castro, J. R., et al. (1986) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(86)90412-8 · Cited by 130
On-line re-optimization of prostate IMRT plans for adaptive radiation therapy
Wu, Q., Thongphiew, D., Wang, Z., Mathayomchan, B., Chankong, V., Yoo, S., Lee, W. R., & Yin, F.-F. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/3/011 · Cited by 127
Self-citationInvestigation of the support vector machine algorithm to predict lung radiation‐induced pneumonitis
Chen, S., Zhou, S., Yin, F.-F., Marks, L. B., & Das, S. K. (2007) · Medical Physics · doi:10.1118/1.2776669 · Cited by 96
Self-citation
Cited by
Machine learning in medical applications: a review of state-of-the-art methods
Shehab, M., Abualigah, L., Shambour, Q., Abu-Hashem, M. A., Shambour, M. K. Y., Alsalibi, A. I., & Gandomi, A. H. (2022) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2022.105458 · Cited by 542
Big Data and machine learning in radiation oncology: State of the art and future prospects
Bibault, J.-E., Giraud, P., & Burgun, A. (2016) · Cancer Letters · doi:10.1016/j.canlet.2016.05.033 · Cited by 346
Artificial intelligence in radiation oncology: A specialty-wide disruptive transformation?
Thompson, R. F., Valdes, G., Fuller, C. D., Carpenter, C. M., Morin, O., Aneja, S., Lindsay, W. D., Aerts, H. J. W. L., Agrimson, B., Deville, C., et al. (2018) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2018.05.030 · Cited by 258
Artificial intelligence in radiotherapy
Li, G., Wu, X., & Ma, X. (2022) · Seminars in Cancer Biology · doi:10.1016/j.semcancer.2022.08.005 · Cited by 46
An Interpretable Planning Bot for Pancreas Stereotactic Body Radiation Therapy
Zhang, J., Wang, C., Sheng, Y., Palta, M., Czito, B., Willett, C., Zhang, J., Jensen, P. J., Yin, F.-F., Wu, Q., et al. (2021) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2020.10.019 · Cited by 41
Self-citation
Metadata
- Authors
- Zhu, X., Ge, Y., Li, T., Thongphiew, D., Yin, F., & Wu, Q. J.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2011-01-11
- Volume
- 38
- Issue
- 2
- Pages
- 719-726
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W1963932209
- Cited by
- 324
- References
- 11
- FWCI
- 11.11
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A planning quality evaluation tool for prostate adaptive IMRT based on machine learning. https://app.cochat.ai/papers/10.1118/1.3539749
- The paper
- Zhu, X., Ge, Y., Li, T., Thongphiew, D., Yin, F., & Wu, Q. J. (2011). A planning quality evaluation tool for prostate adaptive IMRT based on machine learning. Medical Physics. https://doi.org/10.1118/1.3539749
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.