CT effective dose per dose length product using ICRP 103 weighting factors
The DOI matches its Crossref record.
Abstract
Purpose: To generate effective dose per unit dose length product (E/DLP) conversion factors incorporating ICRP Publication 103 tissue weighting factors. Methods: Effective doses for CT examinations were obtained using the IMPACT Dosimetry Calculator using all 23 dose data sets that are offered by this spreadsheet. CT examinations were simulated for scans performed along the patient long axis for each dosimetry data set using a 4 cm beam width ranging from the upper thighs to top of the head. Five basic body regions (head, neck, chest, abdomen, and pelvis), as well as combinations of the regions (head/neck, chest/abdomen, abdomen/pelvis, and chest/abdomen/pelvis) and whole body CT scans were investigated. Correction factors were generated that can be applied to convert E/DLP conversion factors based on ICRP 60 data to conversion factors that are valid for ICRP 103 data (i.e., ). Results: Use of ICRP 103 weighting factors increase effective doses for head scans by, for chest scans by , and decrease effective doses for pelvis scans by . Current E/DLP conversion factors are estimated to be for head CT examinations and range between 14 and for body CT examinations. Conclusions: Factors that enable patient CT doses to be adjusted to account for ICRP 103 tissue weighting factors are provided, which result in E/DLP factors that were increased in head and chest CT, reduced in pelvis CT, and showed no marked change in neck and abdomen CT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
NATIONAL DIAGNOSTIC REFERENCE LEVEL INITIATIVE FOR COMPUTED TOMOGRAPHY EXAMINATIONS IN KENYA
Korir, G. K., Wambani, J. S., Korir, I. K., Tries, M. A., & Boen, P. K. (2015) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncv020 · Cited by 52
Effective radiation doses of CT examinations in Japan: a nationwide questionnaire-based study
Matsunaga, Y., Kawaguchi, A., Kobayashi, K., Kobayashi, M., Asada, Y., Minami, K., Suzuki, S., & Chida, K. (2016) · The British Journal of Radiology · doi:10.1259/bjr.20150671 · Cited by 29
Patient doses using multidetector computed tomography scanners in Kenya
Korir, G. K., Wambani, J. S., & Korir, I. K. (2012) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncr484 · Cited by 8
Metadata
- Authors
- Huda, W., Magill, D., & He, W.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2011-02-14
- Volume
- 38
- Issue
- 3
- Pages
- 1261-1265
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2007003210
- Cited by
- 173
- References
- 0
- FWCI
- 9.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: CT effective dose per dose length product using ICRP 103 weighting factors. https://app.cochat.ai/papers/10.1118/1.3544350
- The paper
- Huda, W., Magill, D., & He, W. (2011). CT effective dose per dose length product using ICRP 103 weighting factors. Medical Physics. https://doi.org/10.1118/1.3544350
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.