The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A novel computer-aided lung nodule detection system for CT images: Novel CAD system for CT lung nodule detection
Abstract
PURPOSE: The paper presents a complete computer-aided detection (CAD) system for the detection of lung nodules in computed tomography images. A new mixed feature selection and classification methodology is applied for the first time on a difficult medical image analysis problem. METHODS: The CAD system was trained and tested on images from the publicly available Lung Image Database Consortium (LIDC) on the National Cancer Institute website. The detection stage of the system consists of a nodule segmentation method based on nodule and vessel enhancement filters and a computed divergence feature to locate the centers of the nodule clusters. In the subsequent classification stage, invariant features, defined on a gauge coordinates system, are used to differentiate between real nodules and some forms of blood vessels that are easily generating false positive detections. The performance of the novel feature-selective classifier based on genetic algorithms and artificial neural networks (ANNs) is compared with that of two other established classifiers, namely, support vector machines (SVMs) and fixed-topology neural networks. A set of 235 randomly selected cases from the LIDC database was used to train the CAD system. The system has been tested on 125 independent cases from the LIDC database. RESULTS: The overall performance of the fixed-topology ANN classifier slightly exceeds that of the other classifiers, provided the number of internal ANN nodes is chosen well. Making educated guesses about the number of internal ANN nodes is not needed in the new feature-selective classifier, and therefore this classifier remains interesting due to its flexibility and adaptability to the complexity of the classification problem to be solved. Our fixed-topology ANN classifier with 11 hidden nodes reaches a detection sensitivity of 87.5% with an average of four false positives per scan, for nodules with diameter greater than or equal to 3 mm. Analysis of the false positive items reveals that a considerable proportion (18%) of them are smaller nodules, less than 3 mm in diameter. CONCLUSIONS: A complete CAD system incorporating novel features is presented, and its performance with three separate classifiers is compared and analyzed. The overall performance of our CAD system equipped with any of the three classifiers is well with respect to other methods described in literature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Algorithm for Least-Squares Estimation of Nonlinear Parameters
Marquardt, D. W. (1963) · Journal of the Society for Industrial and Applied Mathematics · doi:10.1137/0111030 · Cited by 30,728
Cited by
Setio, A. A. A., Traverso, A., de Bel, T., Berens, M. S. N., Bogaard, C. V. D., Cerello, P., Chen, H., Dou, Q., Fantacci, M. E., Geurts, B., et al. (2017) · Medical Image Analysis · doi:10.1016/j.media.2017.06.015 · Cited by 1,374
Self-citationMultilevel Contextual 3-D CNNs for False Positive Reduction in Pulmonary Nodule Detection
Dou, Q., Chen, H., Yu, L., Qin, J., & Heng, P.-A. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2613502 · Cited by 582
Automated pulmonary nodule detection in CT images using deep convolutional neural networks
Xie, H., Yang, D., Sun, N., Chen, Z., & Zhang, Y. (2019) · Pattern Recognition · doi:10.1016/j.patcog.2018.07.031 · Cited by 459
An Automatic Detection System of Lung Nodule Based on Multigroup Patch-Based Deep Learning Network
Jiang, H., Ma, H., Qian, W., Gao, M., & Li, Y. (2018) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2017.2725903 · Cited by 280
Computer-Aided Diagnosis Systems for Lung Cancer: Challenges and Methodologies
El-Baz, A., Beache, G. M., Gimel'farb, G., Suzuki, K., Okada, K., Elnakib, A., Soliman, A., & Abdollahi, B. (2013) · International Journal of Biomedical Imaging · doi:10.1155/2013/942353 · Cited by 277
Automatic detection of subsolid pulmonary nodules in thoracic computed tomography images
Jacobs, C., van Rikxoort, E. M., Twellmann, T., Scholten, E. T., de Jong, P. A., Kuhnigk, J.-M., Oudkerk, M., de Koning, H. J., Prokop, M., Schaefer-Prokop, C., et al. (2014) · Medical Image Analysis · doi:10.1016/j.media.2013.12.001 · Cited by 262
Metadata
- Authors
- Tan, M., Deklerck, R., Jansen, B., Bister, M., & Cornelis, J.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2011-09-22
- Volume
- 38
- Issue
- 10
- Pages
- 5630-5645
- ISSN
- 0094-2405 (ISSN-L)
- OpenAlex
- W2068609255
- Cited by
- 221
- References
- 1
- FWCI
- 10.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.