The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
iCycle: Integrated, multicriterial beam angle, and profile optimization for generation of coplanar and noncoplanar IMRT plans: iCycle: multicriteria beam angle optimization
Abstract
PURPOSE: To introduce iCycle, a novel algorithm for integrated, multicriterial optimization of beam angles, and intensity modulated radiotherapy (IMRT) profiles. METHODS: A multicriterial plan optimization with iCycle is based on a prescription called wish-list, containing hard constraints and objectives with ascribed priorities. Priorities are ordinal parameters used for relative importance ranking of the objectives. The higher an objective priority is, the higher the probability that the corresponding objective will be met. Beam directions are selected from an input set of candidate directions. Input sets can be restricted, e.g., to allow only generation of coplanar plans, or to avoid collisions between patient/couch and the gantry in a noncoplanar setup. Obtaining clinically feasible calculation times was an important design criterium for development of iCycle. This could be realized by sequentially adding beams to the treatment plan in an iterative procedure. Each iteration loop starts with selection of the optimal direction to be added. Then, a Pareto-optimal IMRT plan is generated for the (fixed) beam setup that includes all so far selected directions, using a previously published algorithm for multicriterial optimization of fluence profiles for a fixed beam arrangement Breedveld et al. [Phys. Med. Biol. 54, 7199-7209 (2009)]. To select the next direction, each not yet selected candidate direction is temporarily added to the plan and an optimization problem, derived from the Lagrangian obtained from the just performed optimization for establishing the Pareto-optimal plan, is solved. For each patient, a single one-beam, two-beam, three-beam, etc. Pareto-optimal plan is generated until addition of beams does no longer result in significant plan quality improvement. Plan generation with iCycle is fully automated. RESULTS: Performance and characteristics of iCycle are demonstrated by generating plans for a maxillary sinus case, a cervical cancer patient, and a liver patient treated with SBRT. Plans generated with beam angle optimization did better meet the clinical goals than equiangular or manually selected configurations. For the maxillary sinus and liver cases, significant improvements for noncoplanar setups were seen. The cervix case showed that also in IMRT with coplanar setups, beam angle optimization with iCycle may improve plan quality. Computation times for coplanar plans were around 1-2 h and for noncoplanar plans 4-7 h, depending on the number of beams and the complexity of the site. CONCLUSIONS: Integrated beam angle and profile optimization with iCycle may result in significant improvements in treatment plan quality. Due to automation, the plan generation workload is minimal. Clinical application has started.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pareto navigation—algorithmic foundation of interactive multi-criteria IMRT planning
Monz, M., Küfer, K., Bortfeld, T. R., et al. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/4/011 · Cited by 203
Li, Y., Yao, D., Yao, J. Y., & Chen, W. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/15/002 · Cited by 120
Aleman, D. M., Kumar, A., Ahuja, R. K., Romeijn, H. E., & Dempsey, J. F. (2008) · Journal of Global Optimization · doi:10.1007/s10898-008-9286-x · Cited by 94
Aleman, D. M., Romeijn, H. E., & Dempsey, J. F. (2008) · INFORMS journal on computing · doi:10.1287/ijoc.1080.0279 · Cited by 54
Craft, D., & Monz, M. (2010) · Medical Physics · doi:10.1118/1.3292636 · Cited by 46
Cited by
Development of the open-source dose calculation and optimization toolkit matRad
Wieser, H.-P., Cisternas, E., Wahl, N., Ulrich, S., Stadler, A., Mescher, H., Müller, L.-R., Klinge, T., Gabrys, H., Burigo, L., et al. (2017) · Medical Physics · doi:10.1002/mp.12251 · Cited by 325
Evaluation of a Knowledge-Based Planning Solution for Head and Neck Cancer
Tol, J. P., Delaney, A. R., Dahele, M., Slotman, B. J., & Verbakel, W. F. A. R. (2015) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2014.11.014 · Cited by 279
Automation in intensity modulated radiotherapy treatment planning—a review of recent innovations
Hussein, M., Heijmen, B. J. M., Verellen, D., & Nisbet, A. (2018) · The British Journal of Radiology · doi:10.1259/bjr.20180270 · Cited by 272
Self-citationBarragán-Montero, A. M., Thomas, M., Defraene, G., Michiels, S., Haustermans, K., Lee, J. A., & Sterpin, E. (2021) · Physica Medica · doi:10.1016/j.ejmp.2021.02.026 · Cited by 69
Metadata
- Authors
- Breedveld, S., Storchi, P. R. M., Voet, P. W. J., & Heijmen, B. J. M.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2012-01-31
- Volume
- 39
- Issue
- 2
- Pages
- 951-963
- ISSN
- 0094-2405 (ISSN-L)
- OpenAlex
- W2089547408
- Cited by
- 321
- References
- 5
- FWCI
- 16.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.