Improved kinetic analysis of dynamic PET data with optimized HYPR‐LR
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Purpose: Highly constrained backprojection‐local reconstruction (HYPR‐LR) has made a dramatic impact on magnetic resonance angiography (MRA) and shows promise for positron emission tomography (PET) because of the improvements in the signal‐to‐noise ratio (SNR) it provides dynamic images. For PET in particular, HYPR‐LR could improve kinetic analysis methods that are sensitive to noise. In this work, the authors closely examine the performance of HYPR‐LR in the context of kinetic analysis, they develop an implementation of the algorithm that can be tailored to specific PET imaging tasks to minimize bias and maximize improvement in variance, and they provide a framework for validating the use of HYPR‐LR processing for a particular imaging task. Methods: HYPR‐LR can introduce errors into non sparse PET studies that might bias kinetic parameter estimates. An implementation of HYPR‐LR is proposed that uses multiple temporally summed composite images that are formed based on the kinetics of the tracer being studied (HYPR‐LR‐MC). The effects of HYPR‐LR‐MC and of HYPR‐LR using a full composite formed with all the frames in the study (HYPR‐LR‐FC) on the kinetic analysis of Pittsburgh compound‐B ([11C]‐PIB) are studied. HYPR‐LR processing is compared to spatial smoothing. HYPR‐LR processing was evaluated using both simulated and human studies. Nondisplaceable binding potential (BP ND) parametric images were generated from fifty noise realizations of the same numerical phantom and eight [11 C]‐PIB positive human scans before and after HYPR‐LR processing or smoothing using the reference region Logan graphical method and receptor parametric mapping (RPM2). The bias and coefficient of variation in the frontal and parietal cortex in the simulated parametric images were calculated to evaluate the absolute performance of HYPR‐LR processing. Bias in the human data was evaluated by comparing parametric image BP ND values averaged over large regions of interest (ROIs) to Logan estimates of the BP ND from TACs averaged over the same ROIs. Variance was assessed qualitatively in the parametric images and semiquantitatively by studying the correlation between voxel BP ND estimates from Logan analysis and RPM2. Results: Both the simulated and human data show that HYPR‐LR‐FC overestimates BP ND values in regions of high [11 C]‐PIB uptake. HYPR‐LR‐MC virtually eliminates this bias. Both implementations of HYPR‐LR reduce variance in the parametric images generated with both Logan analysis and RPM2, and HYPR‐LR‐FC provides a greater reduction in variance. This reduction in variance nearly eliminates the noise‐dependent Logan bias. The variance reduction is greater for the Logan method, particularly for HYPR‐LR‐MC, and the variance in the resulting Logan images is comparable to that in the RPM2 images. HYPR‐LR processing compares favorably with spatial smoothing, particularly when the data are analyzed with the Logan method, as it provides a reduction in variance with no loss of spatial resolution. Conclusions: : HYPR‐LR processing shows significant potential for reducing variance in parametric images, and can eliminate the noise‐dependent Logan bias. HYPR‐LR‐FC processing provides the greatest reduction in variance but introduces a positive bias into the BP ND of high‐uptake border regions. The proposed method for forming HYPR composite images, HYPR‐LR‐MC, eliminates this bias at the cost of less variance reduction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Patlak, C. S., & Blasberg, R. G. (1985) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1985.87 · Cited by 1,673
Cited by
Physical activity attenuates age-related biomarker alterations in preclinical AD
Okonkwo, O. C., Schultz, S. A., Oh, J. M., Larson, J., Edwards, D., Cook, D., Koscik, R., Gallagher, C. L., Dowling, N. M., Carlsson, C. M., et al. (2014) · Neurology · doi:10.1212/wnl.0000000000000964 · Cited by 226
“Postprocessing for both PiB and FDG was based on an in-house automated pipeline.(25) We derived distribution volume ratio (DVR) maps from the PiB images using the Logan method, with a cerebellar gray matter reference.”
MethodSelf-citationAmyloid burden and neural function in people at risk for Alzheimer's Disease
Johnson, S. C., Christian, B. T., Okonkwo, O. C., Oh, J. M., Harding, S., Xu, G., Hillmer, A. T., Wooten, D. W., Murali, D., Barnhart, T. E., et al. (2014) · Neurobiology of Aging · doi:10.1016/j.neurobiolaging.2013.09.028 · Cited by 218
Self-citationKLOTHO heterozygosity attenuates APOE4 -related amyloid burden in preclinical AD
Erickson, C. M., Schultz, S. A., Oh, J. M., Darst, B. F., Ma, Y., Norton, D., Betthauser, T., Gallagher, C. L., Carlsson, C. M., Bendlin, B. B., et al. (2019) · Neurology · doi:10.1212/wnl.0000000000007323 · Cited by 70
“Postprocessing was based on an in-house automated pipeline.(29) We derived distribution volume ratio (DVR)maps from the PiB images using the Logan method, with a cerebellar gray matter reference.”
MethodSelf-citationGaitán, J. M., Boots, E. A., Dougherty, R. J., Oh, J. M., Ma, Y., Edwards, D. F., Christian, B. T., Cook, D. B., & Okonkwo, O. C. (2019) · Brain Plasticity · doi:10.3233/bpl-190093 · Cited by 49
Self-citation
Metadata
- Authors
- Floberg, J. M., Mistretta, C. A., Weichert, J. P., Hall, L. T., Holden, J. E., & Christian, B. T.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2012-05-22
- Volume
- 39
- Issue
- 6Part1
- Pages
- 3319-3331
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2042277982
- Cited by
- 45
- References
- 1
- FWCI
- 2.00
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.