The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Ultrasound GLCM texture analysis of radiation‐induced parotid‐gland injury in head‐and‐neck cancer radiotherapy: An in vivo study of late toxicity
Open accessAbstract
Purpose: Xerostomia (dry mouth), secondary to irradiation of the parotid glands, is one of the most common side effects of head‐and‐neck cancer radiotherapy. Diagnostic tools able to accurately and efficiently measure parotid gland injury have yet to be introduced into the clinic. This study's purpose is to investigate sonographic textural features as potential imaging signatures for quantitative assessment of parotid‐gland injury after head‐and‐neck radiotherapy. Methods: The authors have investigated a series of sonographic features obtained from the gray level co‐occurrence matrix (GLCM) – a second order statistical method of texture analysis. These GLCM textural features were selected based on empirical observations that the normal parotid gland exhibits homogeneous echotexture, whereas the postradiotherapy parotid gland often exhibits heterogeneous echotexture. We employed eight sonographic features: (1) angular second moment (ASM), (2) inverse differential moment (IDM), (3) contrast, (4) variance, (5) correlation, (6) entropy, (7) cluster shade, and (8) cluster prominence. Altogether, sonographic properties of the parotid glands were quantified by their degrees of homogeneity (ASM and IDM), heterogeneity (contrast and variance), smoothness (correlation), randomness (entropy), and symmetry (cluster shade and prominence). The sonographic features were tested in a pilot study of 12 postradiotherapy patients and 7 healthy volunteers. The mean follow‐up time for the postradiotherapy patients was 17.2 months (range: 12.1–23.9 months) and the mean radiation dose to the parotid glands was 32.3 Gy (range: 11.0–63.4 Gy). Each participant underwent one ultrasound study in which longitudinal (vertical) ultrasound scans were performed on the bilateral parotids – a total of 24 postirradiation and 14 normal parotid glands were examined. The 14 normal parotid glands served as the control group. A radiologist contoured the parotid glands on the B‐mode images and the sonographic features were computed from the contoured region‐of‐interest. Results: The authors observed significant differences (p < 0.05) in all sonographic features between the normal and postradiotherapy parotid glands. The sonographic findings were consistent with the clinical observations of the ultrasound images: normal parotid glands exhibited homogeneous texture, while the postradiotherapy parotid glands exhibited heterogeneous echotexture (e.g., hyperechoic lines and spots), which likely represents fibrosis. Conclusions: The authors have demonstrated the feasibility of ultrasonic texture evaluation of parotid glands; and the sonographic features may serve as imaging signatures to assess radiation‐induced parotid injury.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Textural Features for Image Classification
Haralick, R. M., Shanmugam, K., & Dinstein, I. (1973) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1973.4309314 · Cited by 22,886
Eisbruch, A., Ten Haken, R. K., Kim, H. M., Marsh, L. H., & Ship, J. A. (1999) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(99)00247-3 · Cited by 922
Cited by
Deep learning in pore scale imaging and modeling
Wang, Y. D., Blunt, M. J., Armstrong, R. T., & Mostaghimi, P. (2021) · Earth-Science Reviews · doi:10.1016/j.earscirev.2021.103555 · Cited by 262
CT radiomics to predict high‐risk intraductal papillary mucinous neoplasms of the pancreas
Chakraborty, J., Midya, A., Gazit, L., Attiyeh, M., Langdon‐Embry, L., Allen, P. J., Do, R. K. G., & Simpson, A. L. (2018) · Medical Physics · doi:10.1002/mp.13159 · Cited by 105
Chakraborty, J., Langdon-Embry, L., Cunanan, K. M., Escalon, J. G., Allen, P. J., Lowery, M. A., O’Reilly, E. M., Gönen, M., Do, R. G., & Simpson, A. L. (2017) · PLOS ONE · doi:10.1371/journal.pone.0188022 · Cited by 85
Yamashita, R., Perrin, T., Chakraborty, J., Chou, J. F., Horvat, N., Koszalka, M. A., Midya, A., Gonen, M., Allen, P., Jarnagin, W. R., et al. (2020) · European Radiology · doi:10.1007/s00330-019-06381-8 · Cited by 76
Qiu, J.-J., Yin, J., Qian, W., Liu, J.-H., Huang, Z.-X., Yu, H.-P., Ji, L., & Zeng, X.-X. (2021) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2020.3021254 · Cited by 36
Metadata
- Authors
- Yang, X., Tridandapani, S., Beitler, J. J., Yu, D. S., Yoshida, E. J., Curran, W. J., & Liu, T.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2012-08-30
- Volume
- 39
- Issue
- 9
- Pages
- 5732-5739
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2090575716
- Cited by
- 179
- References
- 2
- FWCI
- 5.34
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ultrasound GLCM texture analysis of radiation‐induced parotid‐gland injury in head‐and‐neck cancer radiotherapy: An in vivo study of late toxicity. https://app.cochat.ai/papers/10.1118/1.4747526
- The paper
- Yang, X., Tridandapani, S., Beitler, J. J., Yu, D. S., Yoshida, E. J., Curran, W. J., & Liu, T. (2012). Ultrasound GLCM texture analysis of radiation‐induced parotid‐gland injury in head‐and‐neck cancer radiotherapy: An in vivo study of late toxicity. Medical Physics. https://doi.org/10.1118/1.4747526
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.