Evaluation of motion correction methods in human brain PET imaging—A simulation study based on human motion data
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Purpose: Motion correction in PET has become more important as system resolution has improved. The purpose of this study was to evaluate the accuracy of event‐by‐event and frame‐based MC methods in human brain PET imaging. Methods: Motion compensated image reconstructions were performed with static and dynamic simulated high resolution research tomograph data with frame‐based image reconstructions, using a range of measured human head motion data. Image intensities in high‐contrast regions of interest (ROI) and parameter estimates in tracer kinetic models were assessed to evaluate the accuracy of the motion correction methods. Results: Given accurate motion data, event‐by‐event motion correction can reliably correct for head motions. The average ROI intensities and the kinetic parameter estimates VT and BPND were comparable to the true values. The frame‐based motion correction methods with correctly aligned attenuation map using the average of externally acquired motion data or motion data derived from image registration give comparable quantitative accuracy. For large intraframe (>5 mm) motion, the frame‐based methods produced ∼9% bias in ROI intensities, ∼5% in VT, and ∼10% in BPND estimates. In addition, in real studies that lack a ground truth, the normalized weighted residual sum of squared difference is a potential figure‐of‐merit to evaluate the accuracy of motion correction methods. Conclusions: The authors conclude that frame‐based motion correction methods are accurate when the intraframe motion is less than 5 mm and when the attenuation map is accurately aligned. Given accurate motion data, event‐by‐event motion correction can reliably correct for head motion in human brain PET studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jenkinson, M., Bannister, P., Brady, M., & Smith, S. (2002) · NeuroImage · doi:10.1006/nimg.2002.1132 · Cited by 11,888
Multimodality image registration by maximization of mutual information
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563664 · Cited by 4,547
Spatial registration and normalization of images
Friston, K. J., Ashburner, J., Frith, C. D., Poline, J. ‐., Heather, J. D., & Frackowiak, R. S. J. (1995) · Human Brain Mapping · doi:10.1002/hbm.460030303 · Cited by 4,028
Cited by
In vivo measurement of widespread synaptic loss in Alzheimer’s disease with SV2A PET
Mecca, A. P., Chen, M., O'Dell, R. S., Naganawa, M., Toyonaga, T., Godek, T. A., Harris, J. E., Bartlett, H. H., Zhao, W., Nabulsi, N. B., et al. (2020) · Alzheimer's & Dementia · doi:10.1002/alz.12097 · Cited by 288
Self-citationFinnema, S. J., Nabulsi, N. B., Mercier, J., Lin, S.-F., Chen, M.-K., Matuskey, D., Gallezot, J.-D., Henry, S., Hannestad, J., Huang, Y., et al. (2018) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1177/0271678x17724947 · Cited by 218
Self-citationMecca, A. P., O'Dell, R. S., Sharp, E. S., Banks, E. R., Bartlett, H. H., Zhao, W., Lipior, S., Diepenbrock, N. G., Chen, M., Naganawa, M., et al. (2022) · Alzheimer's & Dementia · doi:10.1002/alz.12582 · Cited by 186
Self-citationNaganawa, M., Li, S., Nabulsi, N., Henry, S., Zheng, M.-Q., Pracitto, R., Cai, Z., Gao, H., Kapinos, M., Labaree, D., et al. (2021) · Journal of Nuclear Medicine · doi:10.2967/jnumed.120.249144 · Cited by 138
“Event-by-event motion correction (13) based on measurements with the Polaris Vicra sensor (NDI Systems) was included in the reconstruction.”
MethodSelf-citationFirst-in-Human Assessment of 11C-LSN3172176, an M1 Muscarinic Acetylcholine Receptor PET Radiotracer
Naganawa, M., Nabulsi, N., Henry, S., Matuskey, D., Lin, S.-F., Slieker, L., Schwarz, A. J., Kant, N., Jesudason, C., Ruley, K., et al. (2021) · Journal of Nuclear Medicine · doi:10.2967/jnumed.120.246967 · Cited by 94
Self-citation
Metadata
- Authors
- Jin, X., Mulnix, T., Gallezot, J., & Carson, R. E.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2013-09-10
- Volume
- 40
- Issue
- 10
- Pages
- 102503-102503
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2056000609
- Cited by
- 119
- References
- 3
- FWCI
- 2.85
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.