Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 242

The DOI matches its Crossref record.

A super‐resolution ultrasound method for brain vascular mapping

Open access
OˈReilly, Meaghan A., Hynynen, Kullervo·2013·Medical Physics

Abstract

Purpose: High‐resolution vascular imaging has not been achieved in the brain due to limitations of current clinical imaging modalities. The authors present a method for transcranial ultrasound imaging of single micrometer‐size bubbles within a tube phantom. Methods: Emissions from single bubbles within a tube phantom were mapped through an ex vivo human skull using a sparse hemispherical receiver array and a passive beamforming algorithm. Noninvasive phase and amplitude correction techniques were applied to compensate for the aberrating effects of the skull bone. The positions of the individual bubbles were estimated beyond the diffraction limit of ultrasound to produce a super‐resolution image of the tube phantom, which was compared with microcomputed tomography (micro‐CT). Results: The resulting super‐resolution ultrasound image is comparable to results obtained via the micro‐CT for small tissue specimen imaging. Conclusions: This method provides superior resolution to deep‐tissue contrast ultrasound and has the potential to be extended to provide complete vascular network imaging in the brain.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1118/1.4823762

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 242

Metadata

Authors
OˈReilly, M. A., & Hynynen, K.
Venue
Medical Physics
Publisher
Wiley
Published
2013-10-03
Volume
40
Issue
11
Pages
110701-110701
ISSN
  • 0094-2405 (ISSN-L)
  • 2473-4209
OpenAlex
W2006654193
Cited by
242
References
0
FWCI
5.49
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A super‐resolution ultrasound method for brain vascular mapping. https://app.cochat.ai/papers/10.1118/1.4823762
The paper
OˈReilly, M. A., & Hynynen, K. (2013). A super‐resolution ultrasound method for brain vascular mapping. Medical Physics. https://doi.org/10.1118/1.4823762

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.