Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 230

The DOI matches its Crossref record.

A signal-to-noise calibration procedure for NMR imaging systems: Signal-to-noise calibration for NMR imaging systems

Edelstein, W. A., Bottomley, Paul A., Pfeifer, Leah M.·1984·Medical Physics

Abstract

A nuclear magnetic resonance (NMR) imaging system signal-to-noise calibration technique based on an NMR projection of distilled water in a cylindrical bottle is proposed. This measurement can characterize any arrangement of rf coils in any magnetic field as signal to noise per ml times root Hz. Inductive losses in a typical patient must be included in the calibration, and such losses can be simulated in a particular system by an externally attached resistor(s) appropriate to that system. Alternatively, an rf inductive damping phantom consisting of a conducting loop of wire containing an appropriate resistor is suggested that can be inserted into any NMR imaging coil to simulate subject Q damping. The same resistor can be used, independent of the details of the coil construction. Furthermore, if the loop inductance is tuned out at each frequency with a series capacitor, then the same loop resistance will serve for all frequencies as a good approximation to human subject damping. This "projection method" signal-to-noise ratio is related to the conventional signal-to-noise ratio measured from a Lorentzian-shaped spectral line as psi P = psi L [2/T2]1/2, where psi stands for signal-to-noise ratio, subscripts P and L stand, respectively, for the projection and "Lorentzian" methods, and T2 is the transverse relaxation time of the spectral line used in the Lorentzian method.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1118/1.595484

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 230

Metadata

Authors
Edelstein, W. A., Bottomley, P. A., & Pfeifer, L. M.
Venue
Medical Physics
Publisher
Wiley
Published
1984-03
Volume
11
Issue
2
Pages
180-185
ISSN
0094-2405 (ISSN-L)
OpenAlex
W2011312163
Cited by
230
References
0
FWCI
5.20
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A signal-to-noise calibration procedure for NMR imaging systems: Signal-to-noise calibration for NMR imaging systems. https://app.cochat.ai/papers/10.1118/1.595484
The paper
Edelstein, W. A., Bottomley, P. A., & Pfeifer, L. M. (1984). A signal-to-noise calibration procedure for NMR imaging systems: Signal-to-noise calibration for NMR imaging systems. Medical Physics. https://doi.org/10.1118/1.595484

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.