X-ray diffraction computed tomography
The DOI matches its Crossref record.
Abstract
Coherent scattering of x-ray photons leads to the phenomenon of x-ray diffraction, which is widely used for determining atomic structure in materials science. A technique [x-ray diffraction computed tomography (CT)] is described, analogous to conventional CT, in which the x-ray diffraction properties of a stack of two-dimensional object sections may be imaged. The technique has been investigated using a first generation (single pencil beam) CT scanner to measure small angle coherent scatter, in addition to the customary transmitted radiation. Diffraction data from a standard CT performance phantom obtained with this new technique and with an x-ray diffractometer are compared. The agreement is satisfactory bearing in mind the poor momentum resolution of our apparatus. The dose and sensitivity of x-ray diffraction CT are compared with those of conventional transmission CT. Diffraction patterns of some biological tissues and plastics presented in a companion paper indicate the potential of x-ray diffraction CT for tissue discrimination and material characterization. Finally, possibilities for refinement of the technique by improving the momentum resolution are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Micro-Computed Tomography—Current Status and Developments
Ritman, E. L. (2004) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140130 · Cited by 360
Spatially resolved nanostructural analysis of disordered phases in carbonated alkali-activated slag
McCaslin, E. R., James, M. C., Almer, J., Cai, Z., Kenesei, P., Park, J.-S., & White, C. E. (2025) · Nature Communications · doi:10.1038/s41467-025-67179-5 · Cited by 6
“When carried out using a small beam size at a synchrotron source ( 10× 10 μ m 2 ), the technique can be combined with computed tomography 50 , similar to the more established X-ray diffraction computed tomography (XRD-CT) technique 51 – 53 .”
Metadata
- Authors
- Harding, G., Kosanetzky, J., & Neitzel, U.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 1987-07
- Volume
- 14
- Issue
- 4
- Pages
- 515-525
- ISSN
- 0094-2405 (ISSN-L)
- OpenAlex
- W2043507767
- Cited by
- 212
- References
- 0
- FWCI
- 3.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: X-ray diffraction computed tomography. https://app.cochat.ai/papers/10.1118/1.596063
- The paper
- Harding, G., Kosanetzky, J., & Neitzel, U. (1987). X-ray diffraction computed tomography. Medical Physics. https://doi.org/10.1118/1.596063
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.