The DOI matches its Crossref record.
Image feature analysis and computer-aided diagnosis in digital radiography. I. Automated detection of microcalcifications in mammography: Image feature analysis. I. Microcalcification detection
Abstract
We have investigated the application of computer-based methods to the detection of microcalcifications in digital mammograms. The computer detection system is based on a difference-image technique in which a signal-suppressed image is subtracted from a signal-enhanced image to remove the structured background in a mammogram. Signal-extraction techniques adapted to the known physical characteristics of microcalcifications are then used to isolate microcalcifications from the remaining noise background. We employ Monte Carlo methods to generate simulated clusters of microcalcifications that are superimposed on normal mammographic backgrounds. This allows quantitative evaluation of detection accuracy of the computer method and the dependence of this accuracy on the physical characteristics of the microcalcifications. Our present computer method can achieve a true-positive cluster detection rate of approximately 80% at a false-positive detection rate of one cluster per image. The potential application of such a computer-aided system to mammographic interpretation is demonstrated by its ability to detect microcalcifications in clinical mammograms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Computer-aided diagnosis in medical imaging: historical review, current status and future potential
Doi, K. (2007) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2007.02.002 · Cited by 1,855
Self-citationPisano, E. D., Zong, S., Hemminger, B. M., DeLuca, M., Johnston, R. E., Muller, K., Braeuning, M. P., & Pizer, S. M. (1998) · Journal of Digital Imaging · doi:10.1007/bf03178082 · Cited by 766
Deep Learning in Medical Image Analysis
Chan, H.-P., Samala, R. K., Hadjiiski, L. M., & Zhou, C. (2020) · Advances in Experimental Medicine and Biology · doi:10.1007/978-3-030-33128-3_1 · Cited by 747
Self-citationCurrent status and future potential of computer-aided diagnosis in medical imaging
Doi, K. (2005) · The British Journal of Radiology · doi:10.1259/bjr/82933343 · Cited by 444
Self-citationRegion-based contrast enhancement of mammograms
Morrow, W. M., Paranjape, R. B., Rangayyan, R. M., & Desautels, J. E. L. (1992) · IEEE Transactions on Medical Imaging · doi:10.1109/42.158944 · Cited by 337
Metadata
- Authors
- Chan, H.-P., Doi, K., Galhotra, S., Vyborny, C. J., MacMahon, H., & Jokich, P. M.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 1987-07
- Volume
- 14
- Issue
- 4
- Pages
- 538-548
- ISSN
- 0094-2405 (ISSN-L)
- OpenAlex
- W2027594868
- Cited by
- 342
- References
- 0
- FWCI
- 1.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Image feature analysis and computer-aided diagnosis in digital radiography. I. Automated detection of microcalcifications in mammography: Image feature analysis. I. Microcalcification detection. https://app.cochat.ai/papers/10.1118/1.596065
- The paper
- Chan, H.-P., Doi, K., Galhotra, S., Vyborny, C. J., MacMahon, H., & Jokich, P. M. (1987). Image feature analysis and computer-aided diagnosis in digital radiography. I. Automated detection of microcalcifications in mammography: Image feature analysis. I. Microcalcification detection. Medical Physics. https://doi.org/10.1118/1.596065
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.