Image feature analysis and computer-aided diagnosis in digital radiography. 2. Computerized determination of vessel sizes in digital subtraction angiography: Image feature analysis. 2. Vessel sizes in DSA
The DOI matches its Crossref record.
Abstract
We developed an iterative deconvolution technique to determine the size of a "blurred" vessel in a digital subtraction angiographic (DSA) image by taking into account the unsharpness of the DSA system. Initially, a region of interest over a small segment of the contrast-filled vessel was selected in a DSA image, and the center line of the opacified vessel was determined by polynomial curve fitting of the locations of the peak pixel values along the vessel image. The blurred image profile was then obtained from pixel values across the vessel in a direction perpendicular to the center line. This measured profile was compared iteratively with a calculated profile for various size vessels, which was obtained from a cylindrical vessel model and from the line spread function, until the root-mean-square difference between the two profiles was minimized. The size of a cylindrical vessel yielding the matched profile was considered the best estimate of the unknown vessel size. Studies with a blood vessel phantom indicated that vessels larger than 0.5 mm could be measured with an accuracy and precision of approximately 0.1 mm, which is about 1/3 of the pixel size used in our DSA system. Details of our approach and some clinical vessel images with and without simulated stenotic lesions are presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Computer-aided diagnosis in medical imaging: historical review, current status and future potential
Doi, K. (2007) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2007.02.002 · Cited by 1,855
Self-citationGiger, M. L., Chan, H., & Boone, J. (2008) · Medical Physics · doi:10.1118/1.3013555 · Cited by 311
Computer-aided diagnosis in radiology: potential and pitfalls
Doi, K., MacMahon, H., Katsuragawa, S., Nishikawa, R. M., & Jiang, Y. (1999) · European Journal of Radiology · doi:10.1016/s0720-048x(99)00016-9 · Cited by 230
Self-citationBlur identification by the method of generalized cross-validation
Reeves, S. J., & Mersereau, R. M. (1992) · IEEE Transactions on Image Processing · doi:10.1109/83.148604 · Cited by 213
“ful-astronomy [ 11, medicine [ 2 ], and military reconnaissance [3], for example.”
Artificial intelligence in medicine: what is it doing for us today?
Becker, A. (2019) · Health Policy and Technology · doi:10.1016/j.hlpt.2019.03.004 · Cited by 137
Metadata
- Authors
- Fujita, H., Doi, K., Fencil, L. E., & Chua, K. G.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 1987-07
- Volume
- 14
- Issue
- 4
- Pages
- 549-556
- ISSN
- 0094-2405 (ISSN-L)
- OpenAlex
- W2083491333
- Cited by
- 48
- References
- 0
- FWCI
- 0.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.