The DOI matches its Crossref record.
Clinically relevant optimization of 3-D conformal treatments
Abstract
In this paper a method of computer-aided optimization of 3-D conformal treatment plans is presented which incorporates models to predict the clinical consequences of resulting dose distributions. Even though these models are simplistic, it is submitted that their intelligent use leads to treatment plans which indicate lower normal tissue complications and higher tumor control. Dose distribution data, biological models, and observed normal tissue and tumor response data are used to compute tumor control and normal tissue complication probabilities for each of the critical normal structures encountered in a treatment plan. These quantities are combined into a single score using an objective function which incorporates the importance of each end point as assessed by the physician. Using the "simulated annealing" method of optimization, the beam weights are adjusted to maximize the score. Additional constraints are applied to ensure consistency of the results of optimization with the judgment of the physician. These optimization methods have been applied to conformal treatment plans consisting of multiple fixed fields with conformal field shaping. The results indicate that the methods presented have considerable potential.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Use of Normal Tissue Complication Probability Models in the Clinic
Marks, L. B., Yorke, E. D., Jackson, A., Ten Haken, R. K., Constine, L. S., Eisbruch, A., Bentzen, S. M., Nam, J., & Deasy, J. O. (2010) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2009.07.1754 · Cited by 1,826
A unified approach for inversion problems in intensity-modulated radiation therapy
Censor, Y., Bortfeld, T., Martin, B., & Trofimov, A. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/10/001 · Cited by 831
Intensity-modulated radiotherapy: current status and issues of interest
(2001) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(01)01749-7 · Cited by 767
Machine learning and radiology
Wang, S., & Summers, R. M. (2012) · Medical Image Analysis · doi:10.1016/j.media.2012.02.005 · Cited by 697
Comparing different NTCP models that predict the incidence of radiation pneumonitis
Seppenwoolde, Y., Lebesque, J. V., de Jaeger, K., Belderbos, J. S. A., Boersma, L. J., Schilstra, C., Henning, G. T., Hayman, J. A., Martel, M. K., & Ten Haken, R. K. (2003) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)03986-x · Cited by 472
Metadata
- Authors
- Mohan, R., Mageras, G. S., Baldwin, B., Brewster, L. J., Kutcher, G. J., Leibel, S., Burman, C. M., Ling, C. C., & Fuks, Z.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 1992-07
- Volume
- 19
- Issue
- 4
- Pages
- 933-944
- ISSN
- 0094-2405 (ISSN-L)
- OpenAlex
- W2016389837
- Cited by
- 281
- References
- 0
- FWCI
- 16.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Clinically relevant optimization of 3-D conformal treatments. https://app.cochat.ai/papers/10.1118/1.596781
- The paper
- Mohan, R., Mageras, G. S., Baldwin, B., Brewster, L. J., Kutcher, G. J., Leibel, S., Burman, C. M., Ling, C. C., & Fuks, Z. (1992). Clinically relevant optimization of 3-D conformal treatments. Medical Physics. https://doi.org/10.1118/1.596781
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.