CoChat

Image feature analysis and computer‐aided diagnosis in digital radiography: Automated detection of pneumothorax in chest images

Sanada, Shigeru, Doi, Kunio, MacMahon, Heber · 1992 · Medical Physics
Cited by 57

The DOI matches its Crossref record.

Abstract

In order to aid radiologists in the diagnosis of pneumothorax from chest radiographs, an automated method for detection of subtle pneumothorax is being developed. The computerized method is based on the detection of a fine curved‐line pattern, which is a unique feature of radiographic findings of pneumothorax. Initially, regions of interest (ROIs) are determined in each upper lung area, where subtle pneumothoraces commonly appear. The pneumothorax pattern is enhanced by the selection of edge gradients within a limited range of orientations. Rib edges included in this edge‐enhanced image are removed, based on the locations of posterior ribs that are determined separately. A subtle curved line due to pneumothorax is then detected by means of the Hough transform. The detected pneumothorax pattern is marked on the chest image displayed on a CRT monitor. With the present computer method applied to 50 chest images (28 normals and 22 abnormals with pneumothorax), we were able to detect 77% of pneumothoraces, with 0.44 false‐positives per image.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1118/1.596790

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Sanada, S., Doi, K., & MacMahon, H.
Venue
Medical Physics
Publisher
Wiley
Published
1992-09
Volume
19
Issue
5
Pages
1153-1160
ISSN
  • 0094-2405 (ISSN-L)
  • 2473-4209
OpenAlex
W1993742540
Cited by
57
References
0
FWCI
1.64
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.