The DOI matches its Crossref record.
Analysis of spiculation in the computerized classification of mammographic masses
Abstract
Spiculation is a primary sign of malignancy for masses detected by mammography. In this study, we developed a technique that analyzes patterns and quantifies the degree of spiculation present. Our current approach involves (1) automatic lesion extraction using region growing and (2) feature extraction using radial edge‐gradient analysis. Two spiculation measures are obtained from an analysis of radial edge gradients. These measures are evaluated in four different neighborhoods about the extracted mammographic mass. The performance of each of the two measures of spiculation was tested on a database of 95 mammographic masses using ROC analysis that evaluates their individual ability to determine the likelihood of malignancy of a mass. The dependence of the performance of these measures on the choice of neighborhood was analyzed. We have found that it is only necessary to accurately extract an approximate outline of a mass lesion for the purposes of this analysis since the choice of a neighborhood that accommodates the thin spicules at the margin allows for the assessment of margin spiculation with the radial edge‐gradient analysis technique. The two measures performed at their highest level when the surrounding periphery of the extracted region is used for feature extraction, yielding Az values of 0.83 and 0.85, respectively, for the determination of malignancy. These are similar to that achieved when a radiologist's ratings of spiculation (Az=0.85) are used alone. The maximum value of one of the two spiculation measures (FWHM) from the four neighborhoods yielded an Az of 0.88 in the classification of mammographic mass lesions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Approaches for automated detection and classification of masses in mammograms
Cheng, H. D., Shi, X. J., Min, R., Hu, L. M., Cai, X. P., & Du, H. N. (2006) · Pattern Recognition · doi:10.1016/j.patcog.2005.07.006 · Cited by 538
A review of automatic mass detection and segmentation in mammographic images
Oliver, A., Freixenet, J., Martí, J., Pérez, E., Pont, J., Denton, E. R. E., & Zwiggelaar, R. (2010) · Medical Image Analysis · doi:10.1016/j.media.2009.12.005 · Cited by 398
Antropova, N., Huynh, B. Q., & Giger, M. L. (2017) · Medical Physics · doi:10.1002/mp.12453 · Cited by 389
“and Li et al.(8,16) The resulting FFDM features described quantitative physical properties of the segmented lesion, such as size, shape, texture, and morphology.”
Medical Image Segmentation Methods, Algorithms, and Applications
Norouzi, A., Rahim, M. S. M., Altameem, A., Saba, T., Rad, A. E., Rehman, A., & Uddin, M. (2014) · IETE Technical Review · doi:10.1080/02564602.2014.906861 · Cited by 323
Giger, M. L., Chan, H., & Boone, J. (2008) · Medical Physics · doi:10.1118/1.3013555 · Cited by 311
Self-citation
Metadata
- Authors
- Huo, Z., Giger, M. L., Vyborny, C. J., Bick, U., Lu, P., Wolverton, D. E., & Schmidt, R. A.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 1995-10
- Volume
- 22
- Issue
- 10
- Pages
- 1569-1579
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2017352979
- Cited by
- 173
- References
- 0
- FWCI
- 9.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Analysis of spiculation in the computerized classification of mammographic masses. https://app.cochat.ai/papers/10.1118/1.597626
- The paper
- Huo, Z., Giger, M. L., Vyborny, C. J., Bick, U., Lu, P., Wolverton, D. E., & Schmidt, R. A. (1995). Analysis of spiculation in the computerized classification of mammographic masses. Medical Physics. https://doi.org/10.1118/1.597626
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.