Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 286

The DOI matches its Crossref record.

Unified measurement of observer performance in detecting and localizing target objects on images

Swensson, Richard G.·1996·Medical Physics

Abstract

In this paper methods used to measure observer performance are reviewed, and a simple general model for finding and reporting target objects in gray‐scale image backgrounds is presented. That model provides the basis for a combined measurement of detection and localization performance in various image‐interpretation tasks, whether by human observers or by realized computer algorithms. The model assumes that (1) an observer's detection response and first choice of target location both depend on the “maximally suspicious” finding on an image, (2) a correct (first‐choice) localization of the actual target occurs if and only if its location is selected as the most suspicious, and (3) a target's presence does not alter the degree of suspicion engendered by any other (normal) image findings. Formalization of these assumptions relates the ROC curve, which measures the ability to discriminate between images containing targets and images without targets, to the “Localization Response” (LROC) curve, which measures the conjoint ability to detect and correctly localize the actual targets in those images. A maximum‐likelihood statistical procedure, developed for a two‐parameter “binormal” version of this model, concurrently fits both the ROC and LROC curves from an observer's image ratings and target localizations for a set of image interpretations. The model's application is illustrated (and compared to standard ROC analysis) using sets of rating and localization data from radiologists asked to search chest films for pulmonary nodules. This model is then extended to multiple‐report (“free‐response”) interpretations of multiple‐target images, under the stringent requirement that an observer's detection capability and criterion for reporting possible targets both remain stationary across images and across the successive reports made on a given image. That extended model yields formulations and predictions for the so‐called “Free‐Response” (FROC) curve, and for a recently proposed “Alternative FROC” (AFROC) curve. Tests of that model's “stationarity” assumptions are illustrated using radiologists' free‐search interpretations of chest films for pulmonary nodules, and they suggest that human observers may often violate those assumptions when making multiple‐report interpretations of images.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1118/1.597758

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 286

Metadata

Authors
Swensson, R. G.
Venue
Medical Physics
Publisher
Wiley
Published
1996-10
Volume
23
Issue
10
Pages
1709-1725
ISSN
  • 0094-2405 (ISSN-L)
  • 2473-4209
OpenAlex
W1971724710
Cited by
286
References
0
FWCI
2.80
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Unified measurement of observer performance in detecting and localizing target objects on images. https://app.cochat.ai/papers/10.1118/1.597758
The paper
Swensson, R. G. (1996). Unified measurement of observer performance in detecting and localizing target objects on images. Medical Physics. https://doi.org/10.1118/1.597758

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.