Automatic three‐dimensional inspection of patient setup in radiation therapy using portal images, simulator images, and computed tomography data
The DOI matches its Crossref record.
Abstract
In external beam radiotherapy, conventional analysis of portal images in two dimensions (2D) is limited to verification of in‐plane rotations and translations of the patient. We developed and clinically tested a new method for automatic quantification of the patient setup in three dimensions (3D) using one set of computed tomography (CT) data and two transmission images. These transmission images can be either a pair of simulator images or a pair of portal images. Our procedure adjusts the position and orientation of the CT data in order to maximize the distance through bone in the CT data along lines between the focus of the irradiation unit and bony structures in the transmission images. For this purpose, bony features are either automatically detected or manually delineated in the transmission images. The performance of the method was quantified by aligning randomly displaced CT data with transmission images simulated from digitally reconstructed radiographs. In addition, the clinical performance was assessed in a limited number of images of prostate cancer and parotid gland tumor treatments. The complete procedure takes less than 2 min on a 90‐MHz Pentium PC. The alignment time is 50 s for portal images and 80 s for simulator images. The accuracy is about 1 mm and 1°. Application to clinical cases demonstrated that the procedure provides essential information for the correction of setup errors in case of large rotations (typically larger than 2°) in the setup. The 3D procedure was found to be robust for imperfections in the delineation of bony structures in the transmission images. Visual verification of the results remains, however, necessary. It can be concluded that our strategy for automatic analysis of patient setup in 3D is accurate and robust. The procedure is relatively fast and reduces the human workload compared with existing techniques for the quantification of patient setup in 3D. In addition, the procedure improves the accuracy of treatment verification in 2D in some cases where rotational deviations in the setup occur.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A survey of medical image registration
Maintz, J. B. A., & Viergever, M. A. (1998) · Medical Image Analysis · doi:10.1016/s1361-8415(01)80026-8 · Cited by 3,327
A Review of 3d/2d Registration Methods for Image-Guided Interventions
Markelj, P., Tomaževič, D., Likar, B., & Pernuš, F. (2012) · Medical Image Analysis · doi:10.1016/j.media.2010.03.005 · Cited by 746
“The validation of registration results may be supported by proper visualization such as superimposing the contours of a 3D surface (Feldmar et al., 1997; Gueziec et al., 2000; Hipwell et al., 2003; Jomier et al., 2006; Groher et al., 2007b,a; Zikic et al., 2008; Liu et al., 1998) or edges extracted from DRRs (Gilhuijs…”
BackgroundMethodInfluentialRaaymakers, B. W., Raaijmakers, A. J. E., Kotte, A. N. T. J., Jette, D., & Lagendijk, J. J. W. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/17/019 · Cited by 253
Gradient-based 2-D/3-D rigid registration of fluoroscopic X-ray to CT
Livyatan, H., Yaniv, Z., & Joskowicz, L. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.819288 · Cited by 176
“The gradients need not be computed on all rays, but rather on selected rays in the vicinity of the anatomy contours, as proposed in [39].”
BackgroundRussakoff, D. B., Rohlfing, T., Mori, K., Rueckert, D., Ho, A., Adler, J. R., & Maurer, C. R. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.856749 · Cited by 142
Metadata
- Authors
- Gilhuijs, K. G. A., van de Ven, P. J. H., & van Herk, M.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 1996-03
- Volume
- 23
- Issue
- 3
- Pages
- 389-399
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2051722949
- Cited by
- 142
- References
- 0
- FWCI
- 9.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Automatic three‐dimensional inspection of patient setup in radiation therapy using portal images, simulator images, and computed tomography data. https://app.cochat.ai/papers/10.1118/1.597801
- The paper
- Gilhuijs, K. G. A., van de Ven, P. J. H., & van Herk, M. (1996). Automatic three‐dimensional inspection of patient setup in radiation therapy using portal images, simulator images, and computed tomography data. Medical Physics. https://doi.org/10.1118/1.597801
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.