CoChat

A CT‐based Monte Carlo simulation tool for dosimetry planning and analysis

DeMarco, J. J., Solberg, T. D., Smathers, J. B. · 1998 · Medical Physics
Cited by 212

The DOI matches its Crossref record.

Abstract

The Los Alamos code MCNP4A (M_onte C_arlo N_‐P_article version 4A) is currently used to simulate a variety of problems ranging from nuclear reactor analysis to boron neutron capture therapy. A graphical user interface has been developed that automatically sets up the MCNP4A geometry and radiation source requirements for a three‐dimensional Monte Carlo simulation using computed tomography data. The major drawback for this dosimetry system is the amount of time to obtain a statistically significant answer. A specialized patch file has been developed that optimizes photon particle transport and dose scoring within the standard MCNP4A lattice geometry. The transport modifications produce a performance increase (number of histories per minute) of approximately 4.7 based upon a 6 MV point source centered within a lattice water phantom and voxels. The dose scoring modifications produce a performance increase of approximately 470 based upon a tally section of greater than lattice elements and a voxel size of Homogeneous and heterogeneous benchmark calculations produce good agreement with measurements using a standard water phantom and a high‐ and low‐density heterogeneity phantom. The dose distribution from a typical mediastinum treatment planning setup is presented for qualitative analysis and comparison versus a conventional treatment planning system.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1118/1.598167

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 212

Metadata

Authors
DeMarco, J. J., Solberg, T. D., & Smathers, J. B.
Venue
Medical Physics
Publisher
Wiley
Published
1998-01
Volume
25
Issue
1
Pages
1-11
ISSN
  • 0094-2405 (ISSN-L)
  • 2473-4209
OpenAlex
W2067302262
Cited by
212
References
0
FWCI
21.07
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A CT‐based Monte Carlo simulation tool for dosimetry planning and analysis. https://app.cochat.ai/papers/10.1118/1.598167
The paper
DeMarco, J. J., Solberg, T. D., & Smathers, J. B. (1998). A CT‐based Monte Carlo simulation tool for dosimetry planning and analysis. Medical Physics. https://doi.org/10.1118/1.598167

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.