CoChat

Selective measurement of white matter and gray matter diffusion trace values in normal human brain

Zacharopoulos, Nicholas G., Narayana, Ponnada A. · 1998 · Medical Physics
Cited by 31

The DOI matches its Crossref record.

Abstract

The trace of the diffusion tensor (or simply the trace) is diagnostically valuable for detecting acute ischemic lesions. A number of studies indicate that the trace of human gray matter (GM) and white matter (WM) are quite similar. This is somewhat surprising considering the different cellular environments of GM and WM. It is possible that partial volume averaging (PVA) effects between GM and WM, inherent in many of the ultrafast imaging sequences used for diffusion measurements, are responsible for this observation. In order to minimize PVA effects, the trace values of GM and WM have been selectively measured by implementing double inversion recovery (DIR) echo planar imaging (EPI) pulse sequences. Results on six normal volunteers indicate that the trace values of WM and GM are not statistically different.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1118/1.598424

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 31

Metadata

Authors
Zacharopoulos, N. G., & Narayana, P. A.
Venue
Medical Physics
Publisher
Wiley
Published
1998-10-28
Volume
25
Issue
11
Pages
2237-2241
ISSN
  • 0094-2405 (ISSN-L)
  • 2473-4209
OpenAlex
W2008426579
Cited by
31
References
0
FWCI
2.54
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Selective measurement of white matter and gray matter diffusion trace values in normal human brain. https://app.cochat.ai/papers/10.1118/1.598424
The paper
Zacharopoulos, N. G., & Narayana, P. A. (1998). Selective measurement of white matter and gray matter diffusion trace values in normal human brain. Medical Physics. https://doi.org/10.1118/1.598424

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.