Selective measurement of white matter and gray matter diffusion trace values in normal human brain
The DOI matches its Crossref record.
Abstract
The trace of the diffusion tensor (or simply the trace) is diagnostically valuable for detecting acute ischemic lesions. A number of studies indicate that the trace of human gray matter (GM) and white matter (WM) are quite similar. This is somewhat surprising considering the different cellular environments of GM and WM. It is possible that partial volume averaging (PVA) effects between GM and WM, inherent in many of the ultrafast imaging sequences used for diffusion measurements, are responsible for this observation. In order to minimize PVA effects, the trace values of GM and WM have been selectively measured by implementing double inversion recovery (DIR) echo planar imaging (EPI) pulse sequences. Results on six normal volunteers indicate that the trace values of WM and GM are not statistically different.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Analysis of partial volume effects in diffusion‐tensor MRI
Alexander, A. L., Hasan, K. M., Lazar, M., Tsuruda, J. S., & Parker, D. L. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1105 · Cited by 695
Mukherjee, P., Miller, J. H., Shimony, J. S., Conturo, T. E., Lee, B. C. P., Almli, C. R., & McKinstry, R. C. (2001) · Radiology · doi:10.1148/radiol.2212001702 · Cited by 431
Diffusion tensor imaging of normal and injured developing human brain-a technical review
Neil, J., Miller, J., Mukherjee, P., & Hüppi, P. S. (2002) · NMR in Biomedicine · doi:10.1002/nbm.784 · Cited by 402
Reversible Posterior Leukoencephalopathy Syndrome: Evaluation with Diffusion-Tensor MR Imaging
Mukherjee, P., & McKinstry, R. C. (2001) · Radiology · doi:10.1148/radiology.219.3.r01jn48756 · Cited by 243
Papadakis, N. G., Martin, K. M., Mustafa, M. H., Wilkinson, I. D., Griffiths, P. D., Huang, C. L. ‐., & Woodruff, P. W. R. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10204 · Cited by 93
“The latter voxels were discarded by applying magnitude masking in the bl images (3,4).”
Method
Metadata
- Authors
- Zacharopoulos, N. G., & Narayana, P. A.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 1998-10-28
- Volume
- 25
- Issue
- 11
- Pages
- 2237-2241
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2008426579
- Cited by
- 31
- References
- 0
- FWCI
- 2.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Selective measurement of white matter and gray matter diffusion trace values in normal human brain. https://app.cochat.ai/papers/10.1118/1.598424
- The paper
- Zacharopoulos, N. G., & Narayana, P. A. (1998). Selective measurement of white matter and gray matter diffusion trace values in normal human brain. Medical Physics. https://doi.org/10.1118/1.598424
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.