The DOI matches its Crossref record.
A Study of Brownian Motion Using Light Scattering
Abstract
From the spectrum of light scattered by a suspension of particles in a fluid one can obtain quantitative information about the motion of the particles, including an accurate determination of their diffusion constant. If the incident light source is a laser, and the scattered light falls on the photosurface of a photomultiplier tube, then by measuring the spectrum of the photocurrent one obtains the spectrum of the intensity fluctuations of the scattered light. The intensity of the scattered light is determined by the instantaneous superposition of the phases of the waves scattered from each of the diffusing particles and the intensity fluctuates because the particles move. For particles of known diameter one can predict the spectral shape and width from the diffusion equation. We present a calculation of the spectrum of the field and the spectrum of the intensity of the scattered light and an advanced laboratory experiment and lecture demonstration by which the intensity spectrum can be studied.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Diffuse optics for tissue monitoring and tomography
Durduran, T., Choe, R., Baker, W. B., & Yodh, A. G. (2010) · Reports on Progress in Physics · doi:10.1088/0034-4885/73/7/076701 · Cited by 1,161
Boas, D. A., & Yodh, A. G. (1997) · Journal of the Optical Society of America A · doi:10.1364/josaa.14.000192 · Cited by 606
Optical and non‐optical methods for detection and characterization of microparticles and exosomes
VAN DER POL, E., HOEKSTRA, A. G., STURK, A., OTTO, C., VAN LEEUWEN, T. G., & NIEUWLAND, R. (2010) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2010.04074.x · Cited by 535
Kinetic theory of fibrillogenesis of amyloid β-protein
Lomakin, A., Teplow, D. B., Kirschner, D. A., & Benedek, G. B. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.15.7942 · Cited by 529
Self-citationGoldburg, W. I. (1999) · American Journal of Physics · doi:10.1119/1.19101 · Cited by 515
Metadata
- Authors
- Clark, N. A., Lunacek, J. H., & Benedek, G. B.
- Venue
- American Journal of Physics
- Published
- 1970-05-01
- Volume
- 38
- Issue
- 5
- Pages
- 575-585
- ISSN
- 0002-9505 (ISSN-L)
- 1943-2909
- OpenAlex
- W4238678167
- Cited by
- 162
- References
- 0
- FWCI
- 12.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Study of Brownian Motion Using Light Scattering. https://app.cochat.ai/papers/10.1119/1.1976408
- The paper
- Clark, N. A., Lunacek, J. H., & Benedek, G. B. (1970). A Study of Brownian Motion Using Light Scattering. American Journal of Physics. https://doi.org/10.1119/1.1976408
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.