Objective measures of breathy voice quality obtained using an auditory model
The DOI matches its Crossref record.
Abstract
While several acoustic measures have been proposed to quantify listener ratings of breathy voice quality, most have failed to give a consistent and high correlation with perceptual ratings of breathiness. One reason for these limitations is that most acoustic measures do not address the nonlinear processes that occur in the peripheral auditory system during the auditory perceptual process. It was hypothesized that modeling such nonlinear events during signal processing may provide objective parameters that better correspond to perceptual ratings of breathy voice quality. Ten listeners rated 27 voice stimuli using a five-point rating scale. Acoustic measures were determined from these stimuli and were selected based on their history of having a moderate to strong correlation to perceptual ratings of breathiness. The stimuli were also analyzed using an auditory model proposed by Moore, Glasberg, and Baer [J. Audio Eng. Soc. 45(4), 224–239 (1997)], and new measures were calculated from the output of this model. These measures included the partial loudness of the signal and the loudness of the aspiration noise. Measures obtained from the output of the auditory model were found to account for a high amount of variance in the perceptual ratings of breathiness.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Holbrook, A. L., Krosnick, J. A., & Pfent, A. (2007) · Advances in Telephone Survey Methodology · doi:10.1002/9780470173404.ch23 · Cited by 380
Auditory-Perceptual Evaluation of Disordered Voice Quality
Oates, J. (2009) · Folia Phoniatrica et Logopaedica · doi:10.1159/000200768 · Cited by 294
Mapping emotions into acoustic space: the role of voice production.
Patel, S., Scherer, K. R., Björkner, E., & Sundberg, J. (2011) · Biological Psychology · doi:10.1016/j.biopsycho.2011.02.010 · Cited by 177
Discrimination of pathological voices using a time-frequency approach
Umapathy, K., Krishnan, S., Parsa, V., & Jamieson, D. G. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.842962 · Cited by 149
“• Cepstral peak prominence (CPP): Several studies have shown that [12]–[14] CPP correlates well with breathiness ratings and ratings of dysphonic severity.”
BackgroundMultidirectional Regression (MDR)-Based Features for Automatic Voice Disorder Detection
Muhammad, G., Mesallam, T. A., Malki, K. H., Farahat, M., Mahmood, A., & Alsulaiman, M. (2012) · Journal of Voice · doi:10.1016/j.jvoice.2012.05.002 · Cited by 66
Metadata
- Authors
- Shrivastav, R., & Sapienza, C. M.
- Venue
- The Journal of the Acoustical Society of America
- Publisher
- Acoustical Society of America (ASA)
- Published
- 2003-10-01
- Volume
- 114
- Issue
- 4
- Pages
- 2217-2224
- ISSN
- 0001-4966 (ISSN-L)
- 1520-8524
- OpenAlex
- W1990485849
- Cited by
- 94
- References
- 0
- FWCI
- 1.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Objective measures of breathy voice quality obtained using an auditory model. https://app.cochat.ai/papers/10.1121/1.1605414
- The paper
- Shrivastav, R., & Sapienza, C. M. (2003). Objective measures of breathy voice quality obtained using an auditory model. The Journal of the Acoustical Society of America. https://doi.org/10.1121/1.1605414
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.